Specifications, Battery replacement warnings – Banner SureCross DX81H Battery Supply Module User Manual

Page 2

Advertising
background image

6. After replacing the battery, allow up to 60 seconds for the device to power up.
7. Properly dispose of your used battery according to local regulations by taking it to a hazardous waste collection site, an

e-waste disposal center, or any other facility qualified to accept lithium batteries.

As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn

or expose them to high temperatures. Do not recharge, crush, disassemble, or expose

the contents to water.

The battery may be replaced in explosive gas atmospheres.

Replacement battery model number: BWA-BATT-001. For pricing and availability,

contact Banner Engineering.

Battery Replacement Warnings

WARNING:

Do not replace battery when an explosive dust atmosphere may be present.

The replacement battery MUST be a Banner approved battery, model number BWA-BATT-001.

Use of a different battery will VOID the intrinsic safety rating of this device and may result in an

explosion!

When replacing the battery, the negative end of the battery holder is the side with the spring

terminal. This side is marked with a minus (−) sign.

Do not attempt to recharge the battery. These batteries are not rechargeable. Recharging may

cause serious injury to personnel or damage the equipment. Replace only with factory

recommended batteries.

Specifications

General

Environmental

Estimated Battery Life

19,000 mA·hours

Housing

Polycarbonate housing and rotary dial cover; polyester

labels; EDPM rubber cover gasket; nitrile rubber, non-

sulphur cured button covers
Weight: 0.26 kg (0.57 lbs)
Mounting: #10 or M5 (SS M5 hardware included)
Max. Tightening Torque: 0.56 N·m (5 lbf·in)

Wiring Access

One 1/2-inch NPT with 5-pin Euro-style 150 mm

pigtail QD

Environmental

Rating: IEC IP67; NEMA 6; (See UL section below for

any applicable UL specifications)
Operating Temperature: −40 to 70 °C
Operating Humidity: 95% max. relative (non-

condensing)
Radiated Immunity: 10 V/m, 80-2700 MHz

(EN61000-6-2)

Shock and Vibration

IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz

Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.

Certification

DX99 Polycarbonate Housings

CSA: Class I, Division 1, Groups A, B, C, D (Ex ia IIC / AEx ia IIC T4 ) Certificate: CSA 2008243

LCIE/ATEX: Zone 0 (Category 1G), Temperature Class T4 (II 1 G / Ex ia IIC T4) Certificate: LCIE 08 ATEX

6098 X
Notes: Special Conditions for Safe Use imposed by Intrinsic Safety Certificate LCIE 08 ATEX 6098 X: Ambient

temperature range is –40 to 70 °C. SureCross

®

DX99 FlexPower devices can only be connected to Intrinsically Safe

certified equipment or simple apparatus as defined by EN 60079-11. All connected equipment must comply with the

Entity Parameters (Safety Parameters) listed in the

Control Drawings

(p/n 141513). The device must only use a

lithium battery manufactured by XENO, type XL-205F.

SureCross DX81H Battery Supply Module for the DX99

2

www.bannerengineering.com - tel: 763-544-3164

P/N 141517 Rev. B

Advertising