Output response settings – Banner U-GAGE Q45U Series—Analog User Manual

Page 2

Advertising
background image

• The green LED is solid when power is applied to the sensor and flashes to indicate a current output fault.
• The red LED is solid when an echo is received and flashes at a rate proportional to echo strength.
• The amber LED is solid when the target is within the operating window limits.

The 5-segment moving dot LED indicator displays the relative position of the target within the programmed sensing window. LED #1
flashes when the target is closer than the near limit. LED #5 flashes when the target is beyond the far limit.

Limits

N

1 2 3 4 5

3

4

5

1

2

7

Resp.
Speed

+

6

Figure 1. Analog Q45U Features

1 - Push button for programming sensing window limits
2 - 5-segment target position indicator (N = near)
3 - Green POWER indicator LED
4 - Red SIGNAL indicator LED
5 - Amber OUTPUT indicator LED
6 - Response adjustment
7 - Slots for removing inner cover

Output Response Settings

Important: Remove power before making any internal adjustments.

Using the two slots shown in

Figure 1. Analog Q45U Features

on page 2, a small flat-blade screwdriver may be used to lift up and

remove the black inner cover to expose the 4-position DIP switch. Use these DIP switches to program the output slope, output mode,
loss of echo, and min./max. output value default.

DIP Switch Function

Settings

1

Output slope

On = Output value increases with distance
Off* = Output value decreases with distance

1

ON

2

3

4

Figure 2. DIP Switches for Q45U Sensors

2

Output mode

On = Current output enabled
Off* = Voltage output enabled

3

Loss of echo

On = Min - Max Mode
Off* = Hold Mode

4

Min-Max

On* = Default to maximum output value
Off = Default to minimum output value

* Factory default setting.

Q45U Ultrasonic Sensors with Analog Outputs (Long Range)

2

www.bannerengineering.com - tel: 763-544-3164

P/N 48456 Rev. E