Performance curves – Banner U-GAGE Q45U Series—Analog User Manual

Page 6

Advertising
background image

Step 1

Access Limit

Programming Mode

Step 2

Set First Limit

(Near or Far)

Step 3

Set Second Limit

(Far or Near)

T

T >2 sec

Wait >0.8 seconds

before next input

H

L

T

0.04 sec <T< 0.8 sec

Wait >2 seconds before next input

H

L

T

0.04 sec <T< 0.8 sec

H

L

Figure 5. Remote programming the window limits

Notes regarding remote window limit programming:

1. The push button is disabled during remote limit programming. (The remote programming input is disabled during push button pro-

gramming.)

2. Also see the notes regarding window limit programming.

Performance Curves

Effective Beam with Plate Target (Typical)

Effective Beam with Rod Target (Typical)

Lateral Distance

Sensing Distance

4 in

8 in

12 in

16 in

4 in

8 in

12 in

16 in

100 mm

200 mm

300 mm

100 mm

0

0

200 mm

300 mm

400 mm

400 mm

0

500 mm

20 in

1000 mm

40 in

1500 mm

60 in

2000 mm

80 in

2500 mm

100 in

3000 mm

120 in

3500 mm

140 in

4000 mm

160 in

Lateral Distance

Sensing Distance

4 in

8 in

12 in

16 in

4 in

8 in

12 in

16 in

100 mm

200 mm

300 mm

100 mm

0

0

200 mm

300 mm

400 mm

400 mm

0

500 mm

20 in

1000 mm

40 in

1500 mm

60 in

2000 mm

80 in

2500 mm

100 in

3000 mm

120 in

3500 mm

140 in

4000 mm

160 in

Q45U Ultrasonic Sensors with Analog Outputs (Long Range)

6

www.bannerengineering.com - tel: 763-544-3164

P/N 48456 Rev. E