Push Button

Remote Line

Result

0.04 seconds ≤ “Click” ≤
0.8 seconds

0.04 seconds ≤ T ≤ 0.8
seconds

Access Set Mode

Press and hold Static (-)
push button for more than 2
seconds

Single-pulse the remote line

Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Bar graph: #5 and 6 alternately flash

Set Sensing Con-
dition

Present the sensing condi-
tion and double-click the
Static (-) push button

Present the sensing condi-
tion and double-pulse the re-
mote line

Threshold Conditions Accepted
Power LED: ON
Bar graph: 2 indicators flash together to show the
threshold conditions are accepted
Sensor returns to RUN mode with new settings

Threshold Conditions Unacceptable
Power LED: OFF
Bar graph: #1, 3 and 5, 7 alternately flash to show
failure
Sensor returns to “SET Sensing Condition”

Single-Point Light Set

• Sets a threshold 12.5% below the taught condition.
• Any condition darker than the threshold condition causes the output to change

state.

• Threshold position is adjustable using the “+” and “-” buttons (Manual Adjust).
• Recommended for applications where only one condition is known, for example

a stable light background with varying darker targets.

A single sensing condition is presented, and the sensor positions a threshold 12.5%
below the presented condition. When a condition darker than the threshold is
sensed, the output either turns ON or OFF, depending on the Light/Dark Operate
setting (see

Setup Mode

on page 6).

Threshold position

adjusted by

Manual Adjust

Sensor positions
threshold 12.5% below
the presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Condition
Presented

Light Set and Light/Dark Operate Selection
In Light Operate mode, Light Set teaches the Output ON condition. In Dark Operate mode, Light Set teaches the Output OFF condition.

Push Button

Remote Line

Result

0.04 seconds ≤ “Click” ≤
0.8 seconds

0.04 seconds ≤ T ≤ 0.8
seconds

Access Set Mode

Press and hold Static (-)
push button for more than 2
seconds

Single-pulse the remote
line

Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Bar graph: #5 and 6 alternately flash

Set Sensing Condi-
tion

Present the sensing condi-
tion and click the Static (-)
push button four times

Present the sensing con-
dition and four-pulse the
remote line

Threshold Condition Accepted
Power LED: ON
Bar graph: Indicators #5–8 flash together to show that
the threshold condition is accepted
Sensor returns to RUN mode with new settings