Single-point dark set, Setup mode – Banner WORLD-BEAM QS30 Series User Manual

Page 6

Advertising
background image

Push Button

Remote Line

Result

0.04 seconds ≤ “Click” ≤
0.8 seconds

0.04 seconds ≤ T ≤ 0.8
seconds

Threshold Condition Unacceptable
Power LED: OFF
Bar graph: #1, 3 and 5, 7 alternately flash to show fail-
ure
Sensor returns to “SET Sensing Condition”

Single-Point Dark Set

• Sets a threshold 12.5% above the taught condition.
• Any condition lighter than the threshold condition causes the output to change

state.

• Threshold position is adjustable using the “+” and “-” buttons (Manual Adjust).
• Recommended for applications where only one condition is known, for example a

stable dark background with varying lighter targets.

A single sensing condition is presented, and the sensor positions a threshold 12.5%
above the taught condition. When a condition lighter than the threshold is sensed, the
output either turns ON or OFF, depending on the Light/Dark Operate setting (see

Setup Mode

on page 6).

Threshold position

adjusted by

Manual Adjust

Sensor positions

threshold 12.5% above

the presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Condition

Presented

Dark Set and Light/Dark Operate Selection
In Light Operate mode, Dark Set teaches the Output OFF condition. In Dark Operate mode, Dark Set teaches the Output ON condition.

Push Button

Remote Line

Result

0.04 seconds ≤ “Click” ≤
0.8 seconds

0.04 seconds ≤ T ≤
0.8 seconds

Access Set Mode

Press and hold the Static
(-) push button for more
than 2 seconds

Single-pulse remote
line

Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Bar graph: #5 and 6 alternately flash

Set Sensing Con-
dition

Present the sensing condi-
tion and click the Static (-)
push button five times

Present the sensing
condition and five-pulse
the remote line

Threshold Condition Accepted
Power LED: ON
Bar graph: Indicators #1–4 flash together to show that the
threshold condition is accepted
Sensor returns to Run mode with new settings

Threshold Condition Unacceptable
Power LED: OFF
Bar graph: #1, 3 and 5, 7 alternately flash to show failure
Sensor returns to “Set Sensing Condition”

Setup Mode

Setup mode is used to change sensor output response for:

• Light or Dark operate
• 30-millisecond pulse stretcher (OFF delay), if required.
• 300 μs high-speed response

WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor

6

www.bannerengineering.com - tel: 763-544-3164

P/N 127755 Rev. C

Advertising