R55f series fiber-optic color mark sensors, R55f series sensor specifications – Banner R55F Fiber Optic Series User Manual

Page 10

Advertising
background image

R55F Series Fiber-Optic Color Mark Sensors

page

10

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

R55F Series Sensor Specifications

Supply Input

10 to 30V dc (10% maximum ripple) at less than 70 mA, exclusive of load

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Rating

150 mA max each output @ 25°C (derate

1 mA per °C increase)

OFF-state leakage current: < 5 µA @ 30V dc
ON-state saturation voltage: PNP Output < 1V @ 10 mA and 1.5V @ 150 mA

NPN Output < 200 mV @ 10 mA and 1V @ 150 mA

Output Response

50 microseconds
NOTE: 100 millisecond delay on power-up; outputs do not conduct during this time.

Indicator LEDs

10-segment (green) light bar indicates signal strength
Light Operate (green)
Dark Operate (green)
Outputs Conducting (yellow)
OFF Delay (green): SETUP Mode: OFF — no delay

RUN Mode: OFF — no delay

Flashing — 20 ms delay

ON — 20 or 40 ms Delay

ON — 40 ms delay

Construction

Housing:

Black ABS/polycarbonate blend; nylon fiber clip

mounts to standard 35 mm DIN rail
1 stainless steel right angle bracket and 1 PBT polyester bracket for mounting to flat surfaces also included
with sensor

Environmental Rating

IEC IP67; NEMA 6

Connections

Power: 2 m or 9 m PVC-jacketed 5-conductor cable or 5-pin Euro-style quick-disconnect (QD) connector
Fibers: Fiber clip (no tool required)

Operating Conditions

Temperature: -10° to +55° C (+14° to 131° F)
Maximum Relative Humidity: 90% at 50° C (non-condensing)

Application Notes

• Do not mount the fiber tip directly perpendicular to shiny surfaces; position it at approximately a 15° angle

in relation to the sensing target

• Minimize web or product “flutter” whenever possible to maximize sensing reliability

Output Configuration

Bipolar (NPN and PNP)

Output Protection

Protected against false pulse on power-up and continuous overload or short-circuit of outputs.

Adjustments
(see pages 4 - 9)

Using push buttons (“+” Dynamic and “-” Static):

Manually adjust Switch Point using “+” or “-” buttons
Dynamic TEACH (teach on-the-fly) sensitivity adjustment
Static TEACH sensitivity adjustment
Light operate/Dark operate
OFF Delay select: 0 milliseconds, 20 milliseconds or 40 milliseconds

Using Remote TEACH input (gray wire):

Dynamic TEACH (teach on-the-fly) sensitivity adjustment
Static TEACH sensitivity adjustment
Light operate/Dark operate
OFF Delay select: 0 milliseconds, 20 milliseconds or 40 milliseconds
Push button lockout for security