Dimensions

Cabled Models

QD Models

11.5 mm

(0.45")

66.5 mm

(2.62")

Red LED

Alignment Indicator

Jam Nut

(Supplied)

M30 x 1.5

Thread

ø 15 mm

(0.59")

ø 40.0 mm

(1.57")

45.0 mm

(1.77")

51.5 mm

(2.03")

Hookups

Cabled Models

Quick-Disconnect Models

NAMUR Sensor

Hazardous Area

≤ 15V dc

Power

Output

Sensor
Input

Non-hazardous Area

Associated Apparatus

br
bu

+

+

NAMUR Sensor

Hazardous Area

1

≤ 15V dc

Power

Output

Sensor
Input

Non-hazardous Area

Associated Apparatus

2

br

bu

3

4

+

+

Entity Parameters

Associated Apparatus

Voc ≤ 15V dc
Isc ≤ 35 mA
Ca ≥ *C (cable) + Ci
La ≥ *L (cable) + Li

Sensor Apparatus

Vmax = 30V dc
Imax = 35 mA
Ci = 0
Li = 0
Pi = 131

*C (cable) = 60 pF/ft

*L (cable) = 0.2 uH/ft

Important: Hazardous Area Application
Associated apparatus may include amplifiers and barriers to monitor apparatus supply current which is the apparatus output signal.
Associated apparatus must limit both supply voltage current in the even of failures.