9. STANDARD ADJUSTMENTS

BAS-311F-0, 311F-L, 326F-0

48

(4)

(3)

(1)

15mm - 16mm

35 mm

35 mm

25 mm

25 mm

(3)
(4)

(6)

(5)

(1)

(2)

(6)

(2)

(5)

approx. 2 mm

15 mm

approx.
112 mm

(2)

9-9. Adjusting the wiper

<For vertical wiper (standard)>

1. When the thread wiper solenoid plunger (1) is driven to the full stroke, the wiper (2) should be 15 mm in front of the

needle center. Loosen screws (3) and shift the entire solenoid bracket (4)up or down to adjust.
The standard height from the solenoid bracket (4) bottom to the needle plate top is approximately 112 mm.

2. When the wiper (2) is operated and aligned with the center of the needle bar, the distance from the wiper (2) to needle

tip should be approximately 2 mm. Loosen screw (5) and move the wiper (2) in or out to adjust. As shown in Fig. A,
make sure the wiper (2) does not strike the presser foot (6) or needle.

Note

Check that the wiper (2) is not touching the finger guard.

<For vertical wiper (standard)>

1. Loosen the set screw (2) and move the wiper arm support (3) up or down to adjust so that there is a clearance of 15 -

16 mm between the bottom of the thread wiper and the tip (1) of the needle when the thread wiper is aligned with the
center of the needle bar.

2. After the thread wiper has wiped the thread, loosen the bolt (5) and move the whole solenoid fixing plate (6) up or

down to adjust so that the distance is approximately 25 mm.