12. ERROR CODES

BAS-311F-0, 311F-L, 326F-0

65

Code

Cause

Remedy

E.A0

Start switch was pressed when there was no

sewing available data.

Read sewing data again.

E.A1

Can not detect home position. X-Y feed or

connection of home position sensor is incorrect.

Turn off power and, check X-Y feed and connector P1.

E.c0

Motor PROM is not correctly inserted.

Turn off power and check it.

E.c1

Cooling fan (left one when viewed from front) in

control box does not operate.

Turn off power and check it. Check fan connector.

E.c2

Heat-sink on main PCB is overheating.

Turn off power and clean air inlet port.

E.c3

Overcurrent was detected in X pulse motor.

Turn off power and check it.

E.c4

Overcurrent was detected in Y pulse motor.

Turn off power and check it.

E.c5

Cooling fan (right one when viewed from front) in

control box does not operate.

Turn off power and check it. Check fan connector.

E.d0

Air pressure has dropped.

If not use detector, set OFF memory switch 1d.

E.E0

Control PROM is not correctly inserted.

Turn off power and check it.

E.E1

Main PCB detected communication error.

Turn off power and then on again.

E.E2

Panel PCB detected communication error.

Turn off power and then on again.

E.E3

Incorrect connection of cable between operation

panel and control box.

Turn off power and check it.

E.F0

Solenoid is short-circuited (malfunction of main

circuit board) or power supply relay is not operating

(malfunction of power supply circuit board).

Turn off power and check it.

E.F1

Incorrect connection of cable between power supply

PCB and main PCB.

Turn off power and check connector P20.

E.F2

Over current at power supply PCB.

Turn off power and check it.