10.DIPSWITCH

BAS-311F-0, 311F-L, 326F-0

57

DIP switch

D

SW No.

When ON

D-1

The first two stitches at the sewing start will be sewn at low speed (approx. 260 rpm)

D-2

The last two stitches at the sewing end will be sewn at low speed (approx. 260 rpm)

D-3

-

D-4

The last two stitches at the sewing end will be sewn at low speed (approx. 700 rpm)

D-5

-

D-6

Slow-speed sewing at the sewing start will be canceled

D-7

When the upper shaft is stopped, the motor will change direction and the needle bar will return
to the vicinity of the needle up stop position*

D-8

During an emergency stop, the thread is trimmed and the needle bar stops in the raised position.

* When the motor operates in reverse to raise the needle, the thread take-up will stop at a position which is lower than its

normal stopping position. As a result, the thread take-up will rise slightly at the sewing start, and this may result in the
thread pulling out under certain conditions.