9-12. Checking the input sensor and DIP switch input

1. When the SPLIT NO. indicator (1) is illuminated and the R/W switch (3) is pressed while the TEST switch (2) is being

pressed, the X-SCALE indicator (4) will illuminate and the state of the X home position signal will appear on the display
screen (5).

When sensor is ON

When sensor is OFF

2. Each time the MENU switch (6) is pressed, a different indicator will illuminate and the operating condition for the

corresponding item will appear on the display screen.

When X-SCALE indicator is illuminated

:

X home position sensor

When Y-SCALE indicator is illuminated

:

Y home position sensor

When SPEED indicator is illuminated

:

Needle up signal (synchronizer)

When B.T. COUNTER indicator is illuminated :

24-section signal (synchronizer)

When SPLIT ON. indicator is illuminated

:

Needle down signal (synchronizer)

3. If the settings for DIP switch

A at the side of the operation panel are changed at this time, the number of the changed

switch will appear in the top row of the program number display (7).

4. If the settings for DIP switch

B are changed at this time, the number of the changed switch will appear in the bottom

row of the program number display (7).

5. Press the TEST switch (2). The display will return to normal.
Note

You need to move the DIP switch while the power is still turned on in order to check the DIP switch operation.
However, the power must always be turned off before DIP switch settings can be changed.