INTRODUCTION Manual 0-5120

2-2

2.04 Power Supply Specifications

CutMaster A60 Power Supply Specifications

Input Power

380 VAC (360 - 480 VAC), Three Phase, 50/60 Hz
400 VAC (360 - 480 VAC), Three Phase, 50/60 Hz

Input Power Cable

Power Supply includes input cable.

CutMaster A40 Output

Current

20 - 60 Amps, Continuously Adjustable

CutMaster A60 Output

Current

20 - 80 Amps, Continuously Adjustable

Power Supply Gas

Filtering Ability

Particulates to 5 Microns

CutMaster A40 Power Supply Duty Cycle *

Ambient Temperature

Duty Cycle Ratings @ 40° C (104° F)

Opperating Range 0° - 50° C

IEC

Rating

IEC

Rating

IEC

Rating

All Units

Duty Cycle

40%

60%

100%

Current

60 Amps

50 Amps

30 Amps

DC Voltage

104

100

92

* NOTE: The duty cycle will be reduced if the primary input power (AC) is

low or the output voltage (DC) is higher than shown in this chart.

CutMaster A60 Power Supply Duty Cycle *

Ambient Temperature

Duty Cycle Ratings @ 40° C (104° F)

Opperating Range 0° - 50° C

IEC

Rating

IEC

Rating

IEC

Rating

All Units

Duty Cycle

40%

60%

100%

Current

80 Amps

65 Amps

50 Amps

DC Voltage

112

106

100

* NOTE: The duty cycle will be reduced if the primary input power (AC) is

low or the output voltage (DC) is higher than shown in this chart.

NOTE

IEC Rating is determined as specified by the International Electro-Technical Commission. These specifications

include calculating an output voltage based upon power supply rated current. To facilitate comparison between

power supplies, all manufacturers use this output voltage to determine duty cycle.