CUTMASTER A40, A60

INSTALLATION Manual 0-5120

3T-2

Art # A-08323

Plasma

Start / Stop

Signal

Cutting Machine

OK to Move

3. Connect CNC to the power supply.

3T.03 Setting Up Automation or Machine

Torch

NOTE

An adapter is required to be installed in the

power supply if converting a hand torch system

to operate a machine or automation torch.

WARNING

Disconnect primary power at the source before

disassembling the torch or torch leads.

The Automation and Machine torch include a position-

ing tube with rack and pinch block assembly.

1. Mount the torch assembly on the cutting table.

2. To obtain a clean vertical cut, use a square to

align the torch perpendicular to the surface of

the workpiece.

A-02585

Workpiece

Square

Pinch Block
Assembly

Automated and Machine Torch Set - Up

3. The proper torch parts (shield cup, tip, start

cartridge, and electrode) must be installed for

the type of operation. Refer to Section 4T.08,

Torch Parts Selection for details.