Problem -

Symptom

Possible Cause

Recommended Action

FAULT & 80

PSI indicators

flashing. Gas

flow is cycling on

and off.

1. Torch shield cup is loose.

2. Torch tip, electrode or

starter cartridge missing.

3. Torch start cartridge is

stuck.

4. Open conductor in torch

leads.

5. Problem in the torch and

leads switch circuit.

6. Failed components in unit.

1. Tighten shield cup by hand. Do not overtighten.

2. Turn off power supply. Remove shield cup. Install

missing parts.

3. Turn off power supply. Bleed down system

pressure. Remove shield cup, tip and start

cartridge. Check start cartridge lower end fitting for

free movement. Replace if fitting does not move

freely.

4. Replace torch and leads or return to authorized

service center for repair or replacement.

5. Replace torch and leads or return to authorized

service center for repair or replacement.

6. Return to authorized service center for repair or

replacement.

Nothing happens

when torch

switch or remote

switch is closed

(Or CNC START

signal is active)

No gas flow, DC

LED OFF.

1. Problem in the torch and

leads switch circuit

(Remote pendant switch

circuit).

2. CNC Contoller device not

providing Start signal.

3. Failed components in unit.

1. Take Torch and Leads (Remote Pendant) to

Authorize Repair Facility.

2. Contact Controller manufacturer.

3. Return to authorized service center for repair or

replacement.

FAULT and 85

PSI indicators

flashing.

1. Upper O-Ring on torch

head is in wrong position.

2. Torch starter cartridge is

stuck.

3. Worn or faulty torch parts.

4. Shorted Torch.

5. Temporary Short indicated

by 5 links per second.

6. Power Supply Failure

(Standard rate of blinking)

1. Remove shield cup from torch; check upper O-Ring

position; correct if necessary.

2. Turn off power supply. Bleed down system

pressure. Remove shield cup, tip and starter

cartridge. Check starter cartridge lower end fitting

for free movement. Replace if fitting does not move

reely.

3. Inspect torch consumable parts. Replace if

necessary.

4. Replace torch and leads or return to an authorized

Service center for repair.

5. Release torch switch and reactivate.

6. Return to autorized service center for repair or

replacement.

No Fault lights

on, no arc in

torch.

1. Failed components in unit.

1. Return to an authorized service center for repair.

FAULT and 85

PSI indicators

flashing

1. Internal Error

1. Turn the ON / OFF switch OFF then back ON

again. If that does not clear the fault, return to an

authorized service center for repair.

Pilot arc is on but

cutting arc will not

establish

1. Work cable not connected

to work piece.

2. Wrk cable/connector

broken.

3. Failed components in unit.

1. Connect work cable.

2. Replace work cable.

3. Return to an authorized service center for repair.

Torch cutting is

diminished

1. Incorrect current setting.

2. Worn torch consumables.

3. Poor work cable connection

to work piece.

4. Torch being moved too fast.

5. Excessive oil or water in

torch.

6. Failed components in unit.

1. Check and adjust to proper setting.

2. Check torch consumables and replace as needed.

3. Check the connection of the Work Lead to the work

piece.

4. Reduce cutting speed.

5. Refer to "Check air quality" in section 3 Torch.

6. Return to an authorized service center for repair.