Cutmaster a40, a60 – Tweco A40-A60 CutMaster User Manual

Page 73

Advertising
background image

CUTMASTER A40, A60

Manual 0-5120

SERVICE

5T-1

SECTION 5 TORCH:

SERVICE

5T.01 General Maintenance

NOTE

Refer to Previous "Section 5 System" for com-

mon and fault indicator descriptions.

Cleaning Torch

Even if precautions are taken to use only clean

air with a torch, eventually the inside of the torch

becomes coated with residue. This buildup can

affect the pilot arc initiation and the overall cut

quality of the torch.

WARNING

Disconnect primary power to the system before

disassembling the torch or torch leads.
DO NOT touch any internal torch parts while

the AC indicator light of the Power Supply is

ON.

The inside of the torch should be cleaned with elec-

trical contact cleaner using a cotton swab or soft

wet rag. In severe cases, the torch can be removed

from the leads and cleaned more thoroughly by

pouring electrical contact cleaner into the torch

and blowing it through with compressed air.

CAUTION

Dry the torch thoroughly before reinstalling.

O-Ring Lubrication

An o-ring on the Torch Head and ATC Male Con-

nector requires lubrication on a scheduled basis.

This will allow the o-rings to remain pliable and

provide a proper seal. The o-rings will dry out,

becoming hard and cracked if the lubricant is not

used on a regular basis. This can lead to potential

performance problems.

It is recommended to apply a very light film of

o-ring lubricant (Catalog # 8-4025) to the o-rings

on a weekly basis.

Upper Groove
with Vent Holes
Must Remain Open

Threads

Upper O-Ring
in Correct Groove

Lower O-Ring

Art # A-03725

Torch Head O-Ring

ATC O-Ring

NOTE

DO NOT use other lubricants or grease, they

may not be designed to operate within high

temperatures or may contain “unknown ele-

ments” that may react with the atmosphere.

This reaction can leave contaminants inside

the torch. Either of these conditions can lead

to inconsistent performance or poor parts life.

5T.02 Inspection and Replacement of

Consumable Torch Parts

WARNING

Disconnect primary power to the system before

disassembling the torch or torch leads.
DO NOT touch any internal torch parts while

the AC indicator light of the Power Supply is

ON.

Remove the consumable torch parts as follows:

NOTE

The shield cup holds the tip and starter cartridge

in place. Position the torch with the shield cup

facing upward to prevent these parts from fall-

ing out when the cup is removed.

1. Unscrew and remove the shield cup from the

torch.

Advertising