OPERATION

4-1

SECTION 4 SYSTEM:

OPERATION

4.01 Front Panel Controls / Features

See Illustration for numbering Identification

1. Output Current Control

Sets the desired output current. Output settings

up to 60 Amps may be used for drag cutting, when

hand torch is used and the torch tip contacting

the workpiece or higher for standoff cutting. For

automation current control settings greater than

45 Amps will stop the arc and remove the “OK to

Move” signal when the tip contacts the plate. For

currents below 45 Amps the cutting will continue

even when the tip is in contact with the work.

2. Function Control

Function Control Knob, Used to select between

the different operating modes.

SET

Used to purge the air through the unit

and torch and leads and to adjust gas pressure.

RUN

Used for general cutting operations

RAPID AUTO RESTART

Allows for faster

restarting of the Pilot Arc for uninterrupted cutting.

LATCH

Used for longer hand held

cuts. This feature is disabled while the automation

torch is used, and is enabled when a hand torch is

connected. Once a cutting arc is established, the

torch switch can be released. The cutting arc will

remain on until the torch is lifted away from the

work piece, the torch leaves the edge of the work

piece the torch switch is activated again or if one

of the system interlocks is activated.

3. On Off Power Switch

ON / OFF

Switch controls input power to

the power supply. Up is ON, down is OFF.

4. Air/Gas Pressure Control

The Pressure

+

Control is used in the

"SET" mode to adjust the air/gas pressure. Pull

the knob out to adjust and push in to lock.

5.

AC Indicator

Steady light indicates power supply is ready

for operation. Blinking light indicates unit is in

protective interlock mode. Shut unit off, shut off

or disconnect input power, correct the fault, and

restart the unit. Refer to Section 5 for details.

A

+

PSI

BAR

MAX

MAX

MIN

MIN

!

1

2

3

4

5 6 7 8 9

Art# A-07886

MIN

MAX

10

6.

Temp Indicator

Indicator is normally OFF. Indicator is ON when

internal temperature exceeds normal limits. Let

the unit cool before continuing operation.

7.

Gas Indicator

Indicator is ON when minimum input gas pres-

sure for power supply operation is present. Mini-

mum pressure for power supply operation is not

sufficient for torch operation.

8.

DC Indicator

Indicator is ON when DC output circuit is active.

9.

!

Fault Error Indicator

Indicator is ON when Fault circuit is active. See

section 5 for explanations of fault lights.

10. Pressure Indicators

PSI

BAR

MAX

MAX

MIN

MIN

80
75
70
65

5.5

85

5.9

90

6.3

5.2
4.8
4.5

Art # A-08170

The Indicators will illuminate according to the

pressure set by the Pressure Control Knob (num-

ber 4).