GENERAL INFORMATION

1-1

SECTION 1:

GENERAL INFORMATION

1.01 Notes, Cautions and Warnings

Throughout this manual, notes, cautions, and warn-

ings are used to highlight important information.

These highlights are categorized as follows:

NOTE

An operation, procedure, or background infor-

mation which requires additional emphasis or

is helpful in efficient operation of the system.

CAUTION

A procedure which, if not properly followed,

may cause damage to the equipment.

!

WARNING

A procedure which, if not properly followed,

may cause injury to the operator or others in

the operating area.

1.02 Important Safety Precautions

!

WARNING

OPERATION AND MAINTENANCE OF

PLASMA ARC EQUIPMENT CAN BE

DANGEROUS AND HAZARDOUS TO

YOUR HEALTH.
Plasma arc cutting produces intense electric and

magnetic emissions that may interfere with the

proper function of cardiac pacemakers, hear-

ing aids, or other electronic health equipment.

Persons who work near plasma arc cutting ap-

plications should consult their medical health

professional and the manufacturer of the health

equipment to determine whether a hazard exists.
To prevent possible injury, read, understand

and follow all warnings, safety precautions and

instructions before using the equipment. Call

1-603-298-5711 or your local distributor if you

have any questions.

GASES AND FUMES

Gases and fumes produced during the plasma cut-

ting process can be dangerous and hazardous to your

health.

• Keep all fumes and gases from the breathing area.

Keep your head out of the welding fume plume.

• Use an air-supplied respirator if ventilation is not

adequate to remove all fumes and gases.

• The kinds of fumes and gases from the plasma arc

depend on the kind of metal being used, coatings

on the metal, and the different processes. You

must be very careful when cutting or welding

any metals which may contain one or more of

the following:

Antimony

Chromium Mercury

Arsenic

Cobalt

Nickel

Barium

Copper

Selenium

Beryllium

Lead

Silver

Cadmium

Manganese Vanadium

• Always read the Material Safety Data Sheets

(MSDS) that should be supplied with the material

you are using. These MSDSs will give you the

information regarding the kind and amount of

fumes and gases that may be dangerous to your

health.

• For information on how to test for fumes and

gases in your workplace, refer to item 1 in Sub-

section 1.03, Publications in this manual.

• Use special equipment, such as water or down

draft cutting tables, to capture fumes and gases.

• Do not use the plasma torch in an area where

combustible or explosive gases or materials are

located.

• Phosgene, a toxic gas, is generated from the

vapors of chlorinated solvents and cleansers.

Remove all sources of these vapors.

WARNING: This product contains chemicals,

including lead, known to the State of California

to cause birth defects and other reproductive

harm.

Wash hands after handling.

ELECTRIC SHOCK

Electric Shock can injure or kill. The plasma arc process

uses and produces high voltage electrical energy. This

electric energy can cause severe or fatal shock to the

operator or others in the workplace.

• Never touch any parts that are electrically “live”

or “hot.”

• Wear dry gloves and clothing. Insulate yourself

from the work piece or other parts of the welding

circuit.