Cutmaster a40, a60 – Tweco A40-A60 CutMaster User Manual

Page 26

Advertising
background image

CUTMASTER A40, A60

INSTALLATION Manual 0-5120

3-2

NOTE

The upper screws and lower screws are not the

same. Do not mix them. The upper screws are

for threading into the plastic of the front and

rear panels. DO NOT use the finer threaded

lower screws for this.

Upper

Screws

Lower

Screws

Lower

Screws

Art # A-08317

Slots

2. Carefully pull the Cover up and away from the

unit.

B. Cover Installation

1. Reverse previous procedures for cover instal-

lation.

NOTE

When installing the upper screws, attempt to re-

use the original threads. The easaiest way to do

this is by turning the screw counter-clockwise

until you feel the threads lign up, then begin to

turn the screw clockwise to tighten. Do not

over tighten.

C. Input Power Connections

CAUTION

Check your power source for correct voltage

before plugging in or connecting the unit. The

primary power source, fuse, and any extension

cords used must conform to local electrical code

and the recommended circuit protection and

wiring requirements as specified in Section 2.

All units are shipped from the factory with a

380/400Volt input power cable wired to the input

contactor in the three - phase configuration. The fol-

lowing illustration and directions are for replacing the

input power cable.

Art # A-08546

Three-Phase (3ø) and Jumper Settings

L1

L2

L3
L4

Jumper L1 -L4

L1
L2
L3

GND

L4

Three Phase Input Power Wiring

D. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power sup-

ply and input cable before attempting this

procedure.

These instructions are for changing the input power

and or cable on the 208/230, 400, 460 VAC Power Sup-

ply to Three - Phase input power.

1. Remove the Power Supply cover per instruc-

tions found in this subsection A.

2. Disconnect the original input power cable

from the main input contactor and the chassis

ground connection.

3. Loosen the through - hole protector on the back

panel of the power supply. Pull the original

power cable out of the power supply.

4. Using a customer supplied four - conductor

input power cable for the voltage desired, strip

back the insulation on the individual wires.

5. Pass the cable being used through the access

opening in the back panel of the power supply.

Refer to Section 2 for power cable specifica-

tions.

CAUTION

The primary power source and power cable

must conform to local electrical code and the

recommended circuit protection and wiring

requirements (refer to table in Section 2).

6. Connect the wires as follows.

• Remove the copper bus bar jumper from

L2 and L3 on the contactor. See previous

illustration.

• Green / Yellow wire to Ground.

• Remaining wires to L1, L2 and L3 input. It

does not matter what order these wires are

attached. See the previous illustrations.

Advertising