CUTMASTER A40, A60

SERVICE Manual 0-5120

5-4

5.05 Basic Troubleshooting Guide

WARNING

There are extremely dangerous voltage and power levels present inside this unit. Do not attempt to diagnose

or repair unless you have had training in power electronics measurement and troubleshooting techniques.

Problem -

Symptom

Possible Cause

Recommended Action

ON / OFF Switch

is on but the A/C

Indicator does not

light

1. Primary power disconnect

is in OFF position.

2. Primary fuses / breakers

are blown or tripped.

3. Faulty components in unit.

1. Turn primary power disconnect switch to ON

position.

2. a) Have qualified person check primary fuses /

breakers.

b) Connect unit to known good primary power

receptacle

3. Return to authorized service center for repair or

replacement.

FAULT indicator

flashing, 65 PSI

indicator flashing

1. INPUT VOLTAGE

SELECTION

SWITCH set for incorrect

voltage.

2. Primary input voltage

problem.

3. Faulty components in unit.

1. Turn off power to unit then set INPUT VOLTAGE

SELECTION SWITCH to match primary input

voltage.

2. Have qualified person check primary voltage to

insure it meets unit requirements see section 2.04.

3. Return to authorized service center for repair or

replacement.

TEMPERATURE

indicator on.

FAULT indicator

flashing.

1. Air flow through or around

the unit is obstructed.

2. Duty cycle of the unit has

been exceeded

3. Failed components in unit

1. Refer to clearance information – section 2.04

2. Allow unit to cool.

3. Return to authorized service center for repair or

replacement.

GAS indicator

off, FAULT and

MIN pressure

indicators

flashing.

1. Gas supply not connected

to unit.

2. Gas supply not turned on.

3. Gas supply pressure too

low.

4. AIR PRESSURECONTROL

regulator set too low.

5. Failed components in unit.

1. Connect gas supply to unit.

2. Turn gas supply on.

3. Set air supply inlet pressure to unit to 120 psi.

4. Adjust regulator to set air pressure - see section

4.02.

5. Return to authorized service center for repair or

replacement.

FAULT and 70

PSI indicators

flashing.

1. Shield Cup loose.

2. Torch not properly connect-

ed

to power supply.

3. Problem in torch and leads

PIP circuit.

4. Failed components in unit.

1. Hand tighten the shield cup until it is snug.

2. Insure torch ATC is securely fastened to unit.

3. Replace torch and leads or return to authorized ser-

vice center for repair or replacement.

4. Return to authorized service center for repair or

replacement.

FAULT and 75

PSI indicators

flashing.

1. Start signal is active when

ON/OFF SWITCH is turned

to ON position.

2. Problem in the torch and

leads switch circuit.

3. Failed components in unit.

1. Start can be active for one of the following:

• Hand torch switch held closed

• Hand pendant switch held closed

• CNC START signal is active low

Release the START signal source

2. Replace torch and leads or return to authorized

service center for repair or replacement.

3. Return to authorized service center for repair or

replacement.