3 plasma and secondary connections (continued) – Tweco 15XC Merlin User Manual

Page 25

Advertising
background image

Manual 0-2251

3-3

INSTALLATION PROCEDURES

3.3 PLASMA AND SECONDARY CONNECTIONS (continued)

Input Gas Connections

(Air Operation)

Systems that are set up for operation with shop air require
installation of the air line filter on the plasma input fitting
on the rear panel. These systems are shipped with the
following components:

(1) Air Line Filter Assembly (For Plasma Line)
(2) Hex Nipples
(1) 90° Female Elbow
(1) 90° Street Elbow
(1) Y-Hose Assembly

Refer to Figure 2-B and:

1. Thread the first hex nipple into the 90° female elbow.

2. Thread the other end of the hex nipple into the outlet

of the air filter assembly. Tighten both sides securely.

3. Thread the second hex nipple into the fitting on the

rear panel marked PLASMA.

4. Thread the 90° street elbow into the inlet side of the air

filter assembly.

Figure 3-B Air Line Filter Installation

Air Line Filter Installation

Secondary Gas

Fitting

Y-Hose

Assembly

From Supply

Female Elbow

Plasma Gas

Fitting

Street Elbow

Air Filter Assembly

(Plasma Line Only)

Hex Nipple

A-00902

Hex Nipple

Advertising