3 torch parts selection (continued) – Tweco 15XC Merlin User Manual
Page 41

Manual 0-2251
4-7
OPERATION
4.3 TORCH PARTS SELECTION (continued)
Cutting
Gouging
Air Plasma
Oxygen Plasma
Nitrogen Plasma Argon/Hydrogen Air or Multi-Gas
O
2
Plasma
50 Amp (.043) Tip
Cat. No. 9-5753
O
2
Plasma
100 Amp (.057) Tip
Cat. No. 9-5752
O
2
Plasma
150 Amp (.070) Tip
Cat. No. 9-5751
Air Plasma
50 Amp (.043) Tip
Cat. No. 9-5748
Air Plasma
100 Amp (.055) Tip
Cat. No. 9-5747
Air Plasma
150 Amp (.070) Tip
Cat. No. 9-5746
N
2
Plasma
50 Amp (.043) Tip
Cat. No. 9-5765
N
2
Plasma
100 Amp (.052) Tip
Cat. No. 9-5766
N
2
Plasma
150 Amp (.067) Tip
Cat. No. 9-5767
ArH
2
Plasma
150 Amp (.073) Tip
Cat. No. 9-5775
Gouging Tip
Air or Multi-Gas
85 Amp (.078)
Cat. No. 9-5756
Gouging Tip
Air or Multi-Gas
150 Amp (.120)
Cat. No. 9-5755
Air Plasma Electrode
Cutting or Gouging
Cat. No. 9-5749
O
2
Plasma Electrode
Cutting or Gouging
Cat. No. 9-5760
N
2
or Ar/H
2
Plasma Electrode
Cutting or Gouging
Cat. No. 9-5754
For gouging, select
proper electrode to
correspond to the
type of plasma gas
being used (same as
cutting).
Figure 4-E Tip and Electrode Selection