4 electrical connections, 4 electrical connections -6 – Tweco 15XC Merlin User Manual

Page 28

Advertising
background image

INSTALLATION PROCEDURES

3-6

Manual 0-2251

The PAK 15XC power supply is designed to accept a
variety of input voltages:

• 200/220/230 VAC

• 380/415/460 VAC

• 500/575 VAC

The electrical power source must conform to local electric
code and the following recommended circuit protection
and wiring requirements (see Table 3-A).

1. Check the three-phase electrical power source for line

voltage and proper circuit protection and wiring (see
Table 3-A).

3.4 ELECTRICAL CONNECTIONS

Electrical Requirements

Electrical Connections

Refer to Figure 3-D and:

2. Remove the left side panel of the power supply (as

viewed from the front).

3. Check the bus bar configuration on the input voltage

terminal board . The bus bar configuration must
correspond with the available line voltage.

4. If necessary, re-position the bus bars to correspond to

the available line voltage.

5. Insert the primary power cable through the strain relief

in the rear panel of the power supply.

6. Connect the electrical ground wire to the ground lug

on the base of the unit.

7. The other three leads attach to terminals L1, L2, and L3

on the input terminal board.

WARNING

Disconnect primary power at the source before connect-
ing the primary power cable to the power supply.

Advertising