Leads extension packages are available in 25 ft (7.6 m) or
50 ft (15.2 m) lengths. Leads can be extended up to a
maximum of 150 ft (45.8 m).

Leads extension kits for machine torch systems include:

• Plasma, Secondary, Coolant Supply and Coolant Return

Leads Extensions in 25 or 50 ft (7.6 or 15.2 m) lengths

• Shielded Inner Sleeving - 25 or 50 ft (7.6 or 15.2 m)

• Nylon Outer Sleeving - 25 or 50 ft (7.6 or 15.2 m)

• Shielded Inner Sleeving Connector - 12 in (0.30 m)

• Nylon Outer Sleeving Connector - 24 in (0.61 m)

• (2) Hose Clamps

• Coolant Supply Lead Insulator

• Plasma Lead Insulator

• (2) Union Fittings

5.8 LEADS EXTENSION KITS - MACHINE TORCH

Disconnect primary power to the system before
disassembling the torch, leads, or power supply.

WARNING

Disconnect Existing Leads

NOTE

Connect Leads Extension

to Power Supply

Refer to Figure 5-E and:

1. Remove the hose clamp from the torch leads shield

assembly inside the leads access area to release the
shielded inner sleeving.

2. Disconnect the plasma and secondary leads and

coolant supply and return leads from the bulkhead.

To minimize coolant leaks from the leads during installa-
tion, keep the leads connections above the level of the
torch head and existing leads.

3. Position the extension kit and connect the plasma,

secondary, coolant supply, and coolant return leads
extensions to the bulkhead.

4. Connect the shielded inner sleeving to the torch leads

shield assembly and secure with the hose clamp.