CUSTOMER/OPERATOR SERVICE

5-26

Manual 0-2251

5.11 TROUBLESHOOTING GUIDE (continued)

SYMPTOM

POSSIBLE CAUSE

REMEDY

P. Pilot arc on, no main arc

transfer (torch brought
within range of work)

Q. Main arc starts but goes

out immediately and
main contactor (W1 or
W2) goes off

1. Work cable not connected

2. Defective current control

pot (on front panel or
remote)

1. Fault condition causes

output greater than 175
amps

1. Connect work cable

securely

2. If remote is in use, discon-

nect J15 and set current at
front panel. If transfer is
okay, replace remote. If
remote is not in use, see
Section 5.12-Test M

1. Shorted Q1 or faulty

switching control PC
board. See Section 5.12-
Test K