Manual 0-2251

5-21

CUSTOMER/OPERATOR SERVICE

5.11 TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

REMEDY

A. No front panel LED

indicators lit. Fan and
pump off.

B. AC indicator on. Fan and

pump off.

(Causes 6 and 7 are only
for systems having re-
mote control panel)

1. No primary power. See

also Symptoms C and D

2. Blown fuse (F2)

3. Faulty ON/OFF switch

(SW1)

4. Faulty voltage selection

board

1. No primary power See

also Symptoms C and D

2. Blown fuse (F1 or F2)

3. Faulty ON/OFF switch

(SW1)

4. Faulty voltage selection

board

5. Faulty motor contactor

(MC1 or MC2)

6. Faulty switching control

board (relay K1 not
energized to bypass
remote E-stop function)

7. Remote cable plugged into

J15; remote control panel
not connected on other
end of cable

8. Remote panel E-stop

button activated (or
faulty)

1. Check for proper three-

phase power at input
terminal board

2. Check and replace fuse if

necessary

3. Disconnect primary

power. Check each section
for continuity. Replace
switch if necessary

4. See Sction 5.12-Test A and

replace board if necessary

1. Check for proper three-

phase power at input
terminal board

2. Check and replace fuse if

necessary. See Section
5.12-Test B

3. Disconnect primary

power. Check each section
for continuity. Replace
switch if necessary

4. See Section 5.12-Test A

and replace board if
necessary

5. See Section 5.12-Test C

and replace contactor if
necessary

6. See Section 5.12-Test C,

Step 3

7. Remove cable plug from

J15 or connect remote
panel correctly

8. Twist button clockwise to

release. If necessary, check
for continuity from J37-35
to J37-36