03 specifications/design features, 03 specifications/design features -2 – Tweco PAK Master 150XL User Manual

Page 14

Advertising
background image

INTRODUCTION & DESCRIPTION

2-2

Manual 0-2864

2.03 Specifications/Design Features

A. Power Supply Specifications

The following specifications apply to the Power Supply
only:

1. Front Panel Controls

• ON/OFF, RUN/SET and STANDARD/LATCH

Switches

• Output Current Control

• Work Cable Connection

• Torch Leads Connection

2. Front Panel LED Indicators

• AC

• TEMP

• GAS Pressure/Coolant Flow

• DC Output

3. Rear Panel

• Primary Input Power Cable Strain Relief

• Plasma Gas Supply Connection

• Plasma Gas Regulator/Filter Assembly with Gas

Pressure Gauge and Pressure Adjustment

• Secondary Gas Supply Connection

• Secondary Gas Regulator/Filter Assembly with Gas

Pressure Gauge and Pressure Adjustment

4. Input Power (see NOTES)

208/230/460 VAC (±10%), 50/60 Hz, Three-Phase

220/380-415 VAC (±10%), 50/60 Hz, Three-Phase

575 VAC (±10%), 50/60Hz, Three-Phase

NOTES

Refer to Appendix 1 for suggested input wiring
size, current ratings and circuit protection require-
ments.

Units using 575 VAC input power require instal-
lation of Optional 575V Transformer Assembly.

5. Output Power

Continuously variable from 30 to 120 amps (±5%)

6. Duty Cycle (see NOTE)

NOTE

The duty cycle will be reduced if the primary in-
put voltage (AC) is low or the DC voltage is higher
than shown in the chart.

Ambient

Temperature

104° F

(40° C)

104° F

(40° C)

Duty Cycle

60%

100%

Current

120 Amps

n/a Amps

DC Voltage

128 vdc

n/a vdc

Power Supply Duty Cycle

7. Cut Capacity on Carbon Steel

• Genuine Cut Capacity: 1-1/2 inch (38 mm)

• Severance Cut: 1- 3/4 inch (44 mm)

• Pierce Rating: 5/8 inch (15.9 mm)

8. Pilot Circuitry

Capacitive Discharge (CD), Pulsed DC

9. CNC Interface Signals

Start/Stop and OK-To-Move

10. Coolant Pressure

Internal Service Adjustable (Factory Only)

130 psi (8.8 bar) at zero flow

120 - 125 psi (8.2 - 8.5 bar) at 0.6 gpm (2.3 lpm)

11. Coolant Flow Rate

0.5 gpm (1.9 lpm) with 150 feet (45.7 m) of total torch
and torch leads at 70°F (21°C)

NOTE

The flow rate varies with lead length, torch con-
figuration, ambient temperature, amperage level,
etc.

12. Cooling Capacity

4,000 to 10,000 BTU

NOTE

Maximum value based on “free flow” condition.

13. Coolant Reservoir Capacity

2 gallons (Use Thermal Arc

®

coolant only)

Capable of handling a total of 150 feet (45.7 m) of
torch lead length

14. Overall Dimensions

Height: 45-3/8 inches (1.2 m)

Width: 24-1/2 in (0.6 m)

Depth: 35 inches (0.9 m)

Advertising