background image

Manual 0-2864

3-3

INSTALLATION PROCEDURES

WARNING

Disconnect primary power at the source before as-
sembling or disassembling the power supply, torch
parts, or torch and leads assemblies.

Power supplies are factory-wired for HIGH VOLTAGE,
either 460VAC or 380-415VAC, as ordered. Voltage can
be changed from HIGH VOLTAGE to 208/230 VAC or
220 VAC (low voltage), as follows:

HIGH VOLTAGE

Low Voltage

460 VAC

208/230 VAC

380-415 VAC

220 VAC

To change the voltage selection use the following proce-
dures:

1. Locate the voltage selection block mounted on the in-

put power terminal block on the center chassis.

2. Pull the single wire voltage selection plug from the

auxilliary transformer input connector.

A-02108

Terminal Block

Voltage Selection

Block

Voltage

Selection

Plug

Auxilliary Transformer

Input Connector

SEE OPERATING MANUAL FOR

INSTALLATION INSTRUCTIONS

A

UX.

TRANS

.

HIGH VOLTAGE

208V/230V

Nuts and
Star Washers

Figure 3-2 HIGH VOLTAGE Configuration

3. Remove the the nuts and star washers from the two

unused power studs.

4. Remove the two nuts and star washers securing the

voltage selection block to the terminal block.

5. Pull the voltage selection block up and out from the

terminal block.

6. Turn the voltage selection block 180° then slide the

voltage selection block back onto the terminal block.

7. Reinstall the star washers and nuts.

8. Tighten all the nuts.

NOTE

If changing from low voltage to HIGH VOLTAGE
all nuts must be tightened even if not used on the
terminal block.

9. Insert the single wire voltage selection plug into the

auxilliary transformer input connector.

Auxilliary Transformer
Input Connector

Voltage

Selection

Plug

Terminal

Block

Voltage Selection

Block

A-02071

SEE OPERA TING MANU

AL FOR

INST ALLA

TION INSTRUCTIONS

A

UX.

TRANS

.

HIGH VO

L TA

GE

208V/230V

Nuts and Star Washers

Figure 3-3 Low Voltage Configuration

3.07 Input Power Cable Connections

WARNING

Disconnect primary power at the source before con-
necting the primary power cable to the power sup-
ply.

The primary power cable must be supplied by the end
user and installed to the power supply assembly. Refer
to Appendix 1 for suggested cable sizes.