Tweco PAK Master 150XL User Manual

Page 22

Advertising
background image

INSTALLATION PROCEDURES

3-6

Manual 0-2864

A-02085

Two Stage

Filter

Assembly

Barbed

Hose

Fitting

Gas Supply Hose

Hose

Clamp

Figure 3-7 Shop Air Connections - Optional Two

Stage Air Line Filter Assembly

4. Tighten the barbed fitting.

5. Connect the air supply hose (see NOTE) to the barbed

fitting and secure with a customer supplied hose
clamp.

NOTE

The customer supplied hose must be at least a #4
hose (1/4 inch or 6 mm I.D.) to provide adequate
air flow.

C. Using High Pressure Gas Cylinders Only

NOTES

Refer to the manufacturer’s specifications for in-
stallation and maintenance procedures. Refer to
sales literature for a listing of available high-pres-
sure regulators and accessories.

Do not use an air line filter with high pressure regu-
lators.

1. Examine the cylinder valves to be sure they are clean

and free of oil, grease or any foreign material. Mo-
mentarily open each cylinder valve to blow out any
dust which may be present.

WARNING

Do not stand in front of valve outlet when open-
ing.

2. Each cylinder must be equipped with an adjustable

high-pressure regulator capable of outlet pressures up
to 100 psi (6.9 bar) maximum and flows of up to 400
scfh (188.7 lpm).

CAUTION

Pressure should be set at 100 psi (6.9 bar) at the
high pressure gas cylinder regulator.

3. When using gas cylinders as the plasma and second-

ary gas supplies the connections will depend on the
number of cylinders used. Refer to one of the follow-
ing procedures and make the gas connections.

• Using Single Gas Cylinder for Plasma and Sec-

ondary Gas

If the Plasma and Secondary gas source are to be
the same and will use the same high pressure cyl-
inder, connect the gas regulator supply hose from
the gas cylinder to the Power Supply per the fol-
lowing:

a. Remove the factory installed plug fitting from

the end of the T-Fitting on the "Y" Hose As-
sembly.

b. Install a 1/4 NPT-Insert B (right-hand)

Adapter Fitting (see NOTE) into the end of the
T-Fitting.

NOTE

Adapter Fitting must be supplied by the customer.

c. Connect the customer supplied gas regulator

supply hose directly to the Adapter Fitting.

A-02948

T-Fitting

Gas Regulator

Supply Hose

1/4 NPT - Inert B, R.H

Fitting

Figure 3-8 Connection Using Single Gas Cylinder

Advertising