Tweco PAK Master 150XL User Manual

Page 30

Advertising
background image

OPERATION

4-2

Manual 0-2864

3. RUN/SET Switch

RUN position is used for torch operation. SET po-
sition used for setting gas pressure and purging
lines.

4. AC Power Indicator

Once ON/OFF power switch is set to ON, green
LED indicator will blink ON then OFF for approxi-
mately eight seconds and then stay ON. Indicates
operating power is present in the unit.

5. TEMP Indicator

Normally OFF. Yellow LED indicator will come
ON when the internal temperature sensors detect
temperatures above normal limits. The unit
should be allowed to cool before continuing op-
eration.

6. GAS/Coolant Flow OK Indicator

This LED is both a gas pressure and coolant flow
indicator.

A green LED indicator ON means the input gas
pressure is set to 40 psi (2.8 bar) or higher, and
there is adequate coolant flow of greater than 0.5
gpm

The Indicator will be OFF when the pressure falls
below 40 psi (2.8 bar) or there is not enough cool-
ant flow (less than 0.5 gpm) caused by damaged
hose(s), clogged filter(s), etc.

7. DC Indicator

Green LED indicator will come ON while the torch
switch is pressed.

8. STANDARD/LATCH Switch

Placing the switch in the STANDARD position
requires that the torch switch must be held to
maintain the main cutting arc.

Placing the switch in the LATCH position the main
cutting arc will be maintained after the torch
switch is released.

C. Torch Panel Bulkhead

The Torch Panel Bulkhead is located under the Access
Panel.

1. Plasma (+) Gas Lead Connection

Left-hand thread fitting to connect the torch
plasma lead to the unit.

2. Secondary Gas Lead Connection

Fitting to connect the torch secondary lead to the
unit.

3. Coolant Supply (-) Lead Connection

Fitting to connect the torch coolant supply lead to
the unit.

4. Coolant Return Lead Connection

Left-hand thread fitting to connect the torch cool-
ant return lead to the unit.

5. Torch Lead Shield Stud (see NOTE)

Stud used to secure the torch lead shield ring lug.

NOTE

Used with Shielded Torch Leads only.

6. Control Cable Connector

Connector used to interface the Torch Control
Cable to the unit. In Hand Torch applications in-
terfaces the Torch Switch to the unit. In Machine
Torch applications interfaces either Remote Hand
Pendant Control Cable (unshielded Torch Leads)
or CNC Control Cable (shielded Torch Leads).

A-02881

2

1

3

4

5

6

Figure 4-3 Torch Bulkhead Panel

D. Rear Panel

1. Primary Input Power Cable Strain Relief

Primary input power cable strain relief for the pri-
mary power cable capable of handling the input
voltage designed for this unit. Refer to Section
6.06, Parts List for available cable sizes.