INSTALLATION, OPERATION AND SETUP

Input Power
Each unit incorporates an INRUSH circuit. When the MAIN CIRCUIT SWITCH is turned ON, the inrush circuit

provides pre-charging for the input capacitors. A relay in the Power Control Assembly (PCA) will turn ON after the

input capacitors have charged to operating voltage (after approximately 5 seconds)

NOTE

Damage to the PCA could occur if 265V AC or higher is applied to the Primary Power Cord.

Model

Primary Supply

Cord Size

(Factory Fitted)

Minimum Primary

Current Circuit Size

(Vin/Amps)

Current & Duty Cycle

MIG (GMAW/

FCAW)

STICK (SMAW)

LIFT TIG

(GTAW)

Fabricator

181i

12 AWG (3.3mm²)

208-230V/40A

180A @ 20%

175A @ 20%

208-230V/25A

175A @ 25%

Table 3-2: Primary Circuit Sizes to Achieve Maximum Current

3.05 Electromagnetic Compatibility

WARNING

Extra precautions for Electromagnetic

Compatibility may be required when this

Welding Power Source is used in a domestic

situation.

A. Installation and Use - Users Responsibility
The user is responsible for installing and using the

welding equipment according to the manufacturer’s

instructions. If electromagnetic disturbances are

detected then it shall be the responsibility of the user

of the welding equipment to resolve the situation

with the technical assistance of the manufacturer.

In some cases this remedial action may be as

simple as earthing the welding circuit, see NOTE

below. In other cases it could involve constructing

an electromagnetic screen enclosing the Welding

Power Source and the work, complete with

associated input filters. In all cases, electromagnetic

disturbances shall be reduced to the point where

they are no longer troublesome.

NOTE

The welding circuit may or may not be

earthed for safety reasons. Changing the

earthing arrangements should only be

authorized by a person who is competent to

assess whether the changes will increase the

risk of injury, e.g. by allowing parallel welding

current return paths which may damage the

earth circuits of other equipment. Further

guidance is given in EN 60974-13 Arc

Welding Equipment - Installation and use

(under preparation).

B. Assessment of Area
Before installing welding equipment, the user shall

make an assessment of potential electromagnetic

problems in the surrounding area. The following

shall be taken into account

1. Other supply cables, control cables, signaling

and telephone cables; above, below and adjacent

to the welding equipment.

2. Radio and television transmitters and receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of

industrial equipment.

5. The health of people around, e.g. the use of

pacemakers and hearing aids.

6. Equipment used for calibration and

measurement.

7. The time of day that welding or other activities

are to be carried out.

8. The immunity of other equipment in the

environment: the user shall ensure that other

equipment being used in the environment

is compatible: this may require additional

protection measures.

The size of the surrounding area to be considered

will depend on the structure of the building and other

activities that are taking place. The surrounding area

may extend beyond the boundaries of the premises.