INSTALLATION, OPERATION AND SETUP

!

WARNING

Use the regulator for the gas and pressure

for which it is designed. NEVER alter a

regulator for use with any other gas.

NOTE

Regulators purchased with open 1/8”, 1/4”,

3/8”, or 1/2” NPT ports must be assembled

to their intended system.

1. Note the maximum inlet pressure stamped

on the regulator. DO NOT attach the regulator

to a system that has a higher pressure than

the maximum rated pressure stamped on the

regulator.

2. The regulator body will be stamped “IN” or

“HP” at the inlet port. Attach the inlet port to

the system supply pressure connection.

3. Wrap pipe threads with Teflon tape 1 1/2 to 2

turns to effect a seal. If other sealants are used,

they must be compatible with the gas that will

be used in the system.

4. If gauges are to be attached to the regulator

and the regu lator is stamped and listed by a

third party (i.e. “UL” or “ETL”). The following

requirements must be met:
a) Inlet gauges over 1000 PSIG (6.87 mPa)

shall conform with the requirements of UL

404, “Indicating Pressure Gauges for Com-

pressed Gas Service.”

b) Low pressure gauges must be UL recognized

for the class of regulator they are being used

on according to UL252A.

!

WARNING

DO NOT use a regulator that delivers

pressure exceeding the pressure rating

of the downstream equipment unless

pro visions are made to prevent over-

pressurization (i.e. system relief valve).

Make sure the pressure rating of the down-

stream equipment is compatible with the

maximum delivery pressure of the regulator.

5. Be sure that the regulator has the correct

pressure rating and gas service for the cylinder

used.

6. Carefully inspect the regulator for damaged

threads, dirt, dust, grease, oil, or other flammable

substances. Remove dust and dirt with a clean

cloth. Be sure the inlet swivel filter is clean and

in place. Attach the regulator (Figure 3-2) to the

cylinder valve. Tighten securely with a wrench.

!

WARNING

DO NOT attach or use the regulator if oil,

grease, flamma ble substances or damage is

present! Have a qualified repair technician

clean the regulator or repair any damage.

Art # A-09845

Figure 3-2: Regulator to Cylinder Valve

7. Before opening the cylinder valve, turn the

regulator adjusting screw counterclockwise until

there is no pressure on the adjusting spring and

the screw turns freely.

8. Relief Valve (where provided): The relief valve is

designed to protect the low pressure side of the

regulator from high pres sures. Relief valves are

not intended to protect down stream equipment

from high pressures.

!

WARNING

DO NOT tamper with the relief valve or

remove it from the regulator.

!

WARNING

Stand to the side of the cylinder opposite the

regulator when opening the cylinder valve.

Keep the cylinder valve between you and the

regulator. For your safety, NEVER STAND

IN FRONT OF OR BEHIND A REGULATOR

WHEN OPENING THE CYLINDER VALVE!