13 installing 4" (100mm) diameter spool, Installing 4" (100mm) diameter spool -15, Fabricator 181i – Tweco 181i Thermal Arc Fabricator User Manual

Page 45

Advertising
background image

Fabricator 181i

Manual 0-51

91

3-15

INSTALLATION, OPERATION AND SETUP

4. Gently push the bottom of the front panel upward until the thumb screw is fully exposed.

Art # A-11485

Thumb Screw

Fully Exposed

Push Upward

5. Remove damaged thumb screw and replace with new one.

Art # A-11486

6. To reassemble, reverse steps 1 through 4.

3.13 Installing 4" (100mm) Diameter Spool

As delivered from the factory, the Power Source is fitted with a Wire Spool Hub which accepts a 8" (200mm) diameter

spools. In order to fit a 4" (100mm) diameter spool assemble parts in the sequence shown below in Figure 3-9.
Adjustment of the nut with nylon insert will control the MIG Wire Spool Brake. Clockwise rotation of this nut with

nylon insert tightens the brake. The brake is correctly adjusted when the spool stops within 4" (100mm) to 8"

(200mm) (measured at the outer edge of the spool) after MIG Gun trigger is released. Wire should be slack without

becoming dislodged from the spool.

CAUTION

Overtension of brake will cause rapid wear of mechanical WIREFEED parts, overheating of electrical

components and possibly an increased incidence of electrode wire Burnback into contact tip.

Advertising