Fabricator 181i – Tweco 181i Thermal Arc Fabricator User Manual

Page 51

Advertising
background image

Fabricator 181i

Manual 0-51

91

3-21

INSTALLATION, OPERATION AND SETUP

3.20 Setup for MIG (GMAW) Welding with Gas Shielded MIG Wire

A. Select MIG mode with the process selection control. (Refer to Section 3.10 for further information)
B. Connect the MIG Gun Polarity Lead to the positive welding terminal (+). If in doubt, consult the electrode

wire manufacturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It is

essential, however, that the male plug is inserted and turned securely to achieve a sound electrical connection.

C. Fit the MIG Gun to the Power Source. (Refer to section 3.07 Attaching the Tweco Fusion 180A MIG Gun).
D. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode wire manufacturer.

Welding current flows from the Power Source via heavy duty bayonet type terminals. It is essential, however,

that the male plug is inserted and turned securely to achieve a sound electrical connection.

E. Fit the gas regulator/flow gauge to the shielding gas cylinder (refer to Section 3.14) then connect the shielding

gas hose from the rear of the Power Source to the regulator/flow gauge outlet.

F. Refer to the Weld Guide located on the inside of the wirefeed compartment door for further information.

G. Switch the LOCAL/REMOTE switch inside the wire feed

compartment to LOCAL to use the Power Sources Wirespeed and

Voltage controls.

H. Switch the MIG GUN/SPOOL GUN switch inside

the wire feed compartment to MIG GUN.

!

WARNING

Before connecting the work clamp to the work make sure the Electricity Supply is switched OFF.
Secure the welding grade shielding gas cylinder in an upright position by chaining it to a suitable

stationary support to prevent falling or tipping.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused in

the terminal.
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the

Welding Power Source.

Advertising