INSTALLATION, OPERATION AND SETUP

3-4

Manual 0-5191

C. Methods of Reducing Electromagnetic Emissions

1. Electricity Supply
Welding equipment should be connected to the

Electricity Supply according to the manufacturer’s

recommendations. If interference occurs, it may

be necessary to take additional precautions

such as filtering of the Electricity Supply.

Consideration should be given to shielding the

supply cable of permanently installed welding

equipment in metallic conduit or equivalent.

Shielding should be electrically continuous

throughout it’s length. The shielding should be

connected to the Welding Power Source so that

good electrical contact is maintained between

the conduit and the Welding Power Source

enclosure.

2. Maintenance of Welding Equipment
The welding equipment should be routinely

maintained according to the manufacturer’s

recommendations. All access and service doors

and covers should be closed and properly

fastened when the welding equipment is in

operation. The welding equipment should not be

modified in any way except for those changes

and adjustments covered in the manufacturer’s

instructions. In particular, the spark gaps of

arc striking and stabilizing devices should

be adjusted and maintained according to the

manufacturer’s recommendations.

3. Welding Cables
The welding cables should be kept as short

as possible and should be positioned close

together, running at or close to the floor level.

4. Equipotential Bonding
Bonding of all metallic components in the

welding installation and adjacent to it should

be considered. However. Metallic components

bonded to the work piece will increase the

risk that the operator could receive a shock

by touching the metallic components and the

electrode at the same time. The operator should

be insulated from all such bonded metallic

components.

5. Earthing of the Workpiece
Where the workpiece is not bonded to earth

for electrical safety, nor connected to earth

because of it’s size and position, e.g. ship’s hull

or building steelwork, a connection bonding

the workpiece to earth may reduce emissions

in some, but not all instances. Care should be

taken to prevent the earthing of the workpiece

increasing the risk of injury to users, or damage

to other electrical equipment. Where necessary,

the connection of the workpiece to earth should

be made by direct connection to the workpiece,

but in some countries where direct connection is

not permitted, the bonding should be achieved

by suitable capacitance, selected according to

national regulations.

6. Screening and Shielding
Selective screening and shielding of other cables

and equipment in the surrounding area may

alleviate problems of interference. Screening the

entire welding installation may be considered for

special applications.

3.06 Victor Regulator

Pressure regulator (Figure 3-1) attached to the cylinder valve reduce high cylinder pressures to suitable low working

pressures for welding, cutting, and other applications.

LOW PRESSURE

GAUGE (DELIVERY)

HIGH PRESSURE

GAUGE (SUPPLY)

INLET

CONNECTION

OUTLET

CONNECTION

PRESSURE

ADJUSTING

SCREW

A-09414_AB

Figure 3-1: Victor CS Regulator

Advertising