Tweco HMC-410 Robotic Interface Kit User Manual

Page 15

Advertising
background image

Input Common: JP1

Source (Position 1,2): Current Sourcing (PNP) Outputs from Robot (Default - ABB)

Sink (Position 2,3): Current Sinking (NPN) Outputs from Robot

The inputs can accept inputs from 5 to 24 Volts, AC or DC.

Output Common: JP2

Source (Position 1,2): Current Sourcing (PNP) Outputs to Robot (Default - ABB)

Sink (Position 2,3): Current Sinking (NPN) Outputs to Robot

The outputs can sink or source up to 200mA / 60 Volts max.

870244 37 Position Board (Supplied with 870236-2 Fanuc and 870236-3 Comau Kit)
These boards should be configured to operate with the Fanuc robots as shipped. Should an alternate ar-

rangement be required, consult the following for details.
Output Common: JP1

Sink (Position 1,2): Current Sinking (NPN) Outputs to Robot (Default - Fanuc)

Source (Position 2,3): Current Sourcing (PNP) Outputs to Robot (Comau)

The outputs can sink or source up to 200mA / 60 Volts max.

Input Common: JP2

Sink (Position 1,2): Current Sinking (NPN) Outputs from Robot (Default - Fanuc)

Source (Position 2,3): Current Sourcing (PNP) Outputs from Robot (Comau)

430429-457

June 13, 2002

2-9

Figure 4 870244 37 Pin Amphenol Board

Advertising