Pin

Name

Description

F

Wire On

When the robot control puts +24 VDC on this line with respect to pin J,

the HMC-410 will feed the welding wire. If the power source contactor is

on or the INCH SPEED window is programmed to EEE, the speed is set

by the robot. Otherwise, the speed is set in the INCH SPEED window.

G

Gas On

When the robot control puts +24 VDC on this line with respect to pin J,

the HMC-410 will purge the gas lines.

H

Unused

J

Common

Robot Common

K

Inch

Feedback

This line is set to +24 VDC with respect to pin J by the HMC-410 when

the HMC-410 Inch controls are activated. The purpose of this line is to

tell the robot to return inch speed command voltage on pins W and X

when the HMC-410 is inching wire locally.

L

Weld Inhibit

This line is set to +24 VDC with respect to pin J by the HMC-410 when

the HMC-410 is in test (dry run) mode.

M

Weave

Inhibit

This line is set to +24 VDC with respect to pin J by the HMC-410 when

the operator wants to run an arc with the robot’s weave mode disabled.

N

Wire Stuck

This line is set to +24 VDC with respect to pin J by the HMC-410 when

the HMC-410 senses a wire stuck.

P

Welder

Ready

This line is set to +24 VDC with respect to pin J by the HMC-410 when

the HMC-410 is ready to weld.

Q

+24 VDC

Robot +24 VDC

R

Unused

S

Unused

T

Unused

U

Unused

V

Unused

W

WFS -

Analog return

X

WFS +

This line is a 0 to 10 VDC analog signal, which corresponds to a 0 to 888

inches / minute wire feed speed.