3 (Comau): This mode selects the Comau control. When used with the 37 Pin Amphenol Board (870244),

the following signals on the Comau Harting Connector interface are supported:

Pin

Name

Description

D11

WFS +

This line is a 0 to 10 VDC analog signal, which corresponds to a 0 to 888

inches / minute wire feed speed.

D12

WFS -

Analog return

D13

Shield

D14

VOLT +

This line is a 0 to 10 VDC analog signal, which corresponds to a 0 to

44.0 volts arc voltage (or pulse frequency reference, sometimes called

trim, setting).

D15

VOLT -

Analog return

D16

Shield

D8

D10

A6

Arc On +

Input to the robot designating an arc established condition. These 2

lines are shorted together when there is a arc established.

C5

Arc On -

See Arc On +

A9

Arc Start +

Output from the robot commanding a weld on condition. These 2 lines

are shorted together by the robot to command the HMC-410 to start a

weld. When the contacts are opened, the HMC-410 stops the current

weld.

C16

Arc Start -

See Arc Start +

B9

C9

D1

+ AW

Input to the robot used to sense a wire stuck to the work. When these 2

lines are shorted together, the robot knows that there is a wire stuck to

the work.

D3

- AW

See + AW

A15

Air Blowing +

Output from the robot commanding a purge of shielding gas. These 2

lines are shorted together by the robot to command the HMC-410 to

purge the shielding gas. When the contacts are opened, the HMC-410

stops purging shielding gas.

B15

Air Blowing -

See Air Blowing +

430429-457