02 advanced troubleshooting, 03 test equipment and tools, Factory reset information -2 – Tweco 130i Transarc Service Manual User Manual

Page 44: Advanced troubleshooting -3, Test equipment and tools -3, Transarc 130i, 02 factory reset information

Advertising
background image

TROUBLESHOOTING 6-2 Manual 0-5282

TRANSARC 130i

6 Weld Output operates when

the torch trigger switch is

depressed but the gas valve

does not operate.

A Internal wiring fault

A Check solenoid wiring header is

plugged securely into Control

board. Check solenoid wiring is not

damaged

B Faulty Solenoid

B Replace Solenoid

C Impurity in gas system

causing solenoid to stay

open or closed

C Clean out gas system. Disassemble

solenoid & clean out impurities

D Faulty Power Inverter board

D Replace Power Inverter board

E Faulty Control board

E Replace Control board

Table 6-1: Power Source Faults

6.02 Factory Reset Information

To perform a Factory Reset, press the Trigger Mode Button while turning on the mains power.

Note

NOTE: in some cases a fault may be caused by mis-adjustment of parameters. Performing a factory

reset may correct this.

A-11746