09 pcb connectors, Pcb connectors -8, Transarc 130i – Tweco 130i Transarc Service Manual User Manual
Page 50: 10 pcb connectors
Advertising
TROUBLESHOOTING 6-8 Manual 0-5282
TRANSARC 130i
DC Bus Testing
Multimeter Lead Placement
Voltage with
Supply voltage
OFF
Upper capacitor bank
Positive meter lead to testpoint 1
Negative meter lead to testpoint 2
150-200 VDC
Lower capacitor bank
Positive meter lead to testpoint 2
Negative meter lead to testpoint 3
150-200 VDC
Overall capacitor bank
Positive meter lead to testpoint 1
Negative meter lead to testpoint 3
300-400 VDC
Table 6-8: DC BUS, Multimeter set to measure DC volts
Note: These DC voltages are at nominal mains supply voltage of 240VAC.
6.10 PCB Connectors
1
Inverter PCB
A-11848
Advertising