TROUBLESHOOTING 6-8 Manual 0-5282

TRANSARC 130i

DC Bus Testing

Multimeter Lead Placement

Voltage with

Supply voltage

OFF

Upper capacitor bank

Positive meter lead to testpoint 1

Negative meter lead to testpoint 2

150-200 VDC

Lower capacitor bank

Positive meter lead to testpoint 2

Negative meter lead to testpoint 3

150-200 VDC

Overall capacitor bank

Positive meter lead to testpoint 1

Negative meter lead to testpoint 3

300-400 VDC

Table 6-8: DC BUS, Multimeter set to measure DC volts

Note: These DC voltages are at nominal mains supply voltage of 240VAC.