Manual 0-5282 7-3

DISASSEMBLY PROCEDURE

TRANSARC 130i

7.04 Solenoid Valve and Current Transformer Output Removal

!

Read and follow safety information in Section 6.03 before proceeding with disassembly

1. Unplug control wire.
2. Dismantle two clips over the hose.
3. Unscrew the nut. Then the solenoid valve is disassembled.
4. Disconnect the weld cable from the welding output terminal.
5. Unplug the Current Transformer Output control wire.
6. Then the Current Transformer Output is disassembled.

2

1

2

3

4

5

6

A-11857