Mild steel, O₂ plasma / air shield, This art is for reference only – Tweco Ultra-Cut Torch Data User Manual

Page 12

Advertising
background image

TORCH DATA for Ultra-Cut

8-12

Manual 0-4828

Rev BA

Mild Steel

Flow Rates (SLPM / SCFH)

50A

O₂

Air

Preflow

- / -

30 / 63

O₂ Plasma / Air Shield

Cutflow

6 / 14

12 / 26

Shield Cup

Shield Cap

Shield Gas

Distributor

Tip

Plasma Gas Distributor

Electrode

Cartridge

21-1016

21-1025

21-1272

21-1051

21-1041

21-1069

21-1020

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Material

Thickness

Pre Flow

Pressure

(Air)

Cut Flow Rates / Pressures

Arc

Voltage Cut Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion

Delay

Max Kerf Width

@ Rec. Speed

Plasma (O₂)

Shield (Air)

ga

(in)

inch

(psi)

Ball (psi) Ball (psi) (Volts) (in) ±0.005 (sec)

(in)

(in)

(sec)

(in)

(ipm)

(sec)

(in)

14

-

0.075

70

28

120 20 120

130

0.060

0.0

0.080 0.040

0.8

0.100

280

0.0

0.040

12

-

0.105

70

28

120 20 120

130

0.060

0.0

0.080 0.040

0.8

0.100

270

0.0

0.052

10

-

0.135

70

28

120 20 120

126

0.040

0.4

0.080 0.040

0.4

0.100

160

0.4

0.044

-

3/16

0.188

70

28

120 40 120

130

0.060

0.4

0.100 0.060

0.4

0.110

100

0.4

0.054

-

1/4

0.250

70

28

120 40 120

132

0.060

0.4

0.100 0.060

0.4

0.110

90

0.4

0.062

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Material

Thickness

Pre Flow

Pressure

(Air)

Cut Flow Rates / Pressures

Arc

Voltage Cut Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion

Delay

Max Kerf Width

@ Rec. Speed

Plasma (O₂)

Shield (Air)

(mm)

(Bar)

Ball (Bar) Ball (Bar) (Volts) (mm) ±0.1 (sec) (mm)

(mm)

(sec)

(mm)

(mm/

min)

(sec)

(mm)

2

4.8

28

8.3

20

8.3

130

1.5

0.0

2.0

1.0

0.8

2.5

7080

0.0

1.1

2.5

4.8

28

8.3

20

8.3

130

1.5

0.0

2.0

1.0

0.8

2.5

6910

0.0

1.3

3

4.8

28

8.3

20

8.3

128

1.3

0.2

2.0

1.0

0.6

2.5

5640

0.2

1.2

4

4.8

28

8.3

28

8.3

128

1.2

0.4

2.2

1.2

0.4

2.6

3410

0.4

1.2

5

4.8

28

8.3

40

8.3

130

1.5

0.4

2.5

1.5

0.4

2.8

2500

0.4

1.4

6

4.8

28

8.3

40

8.3

132

1.5

0.4

2.5

1.5

0.4

2.8

2340

0.4

1.5

Marking

Pre Flow

Pressure

(N₂)

Marking Flow Rates /

Pressures

Arc

Voltage

Marking

Height

Pierce Ignition Height

THC and CNC

Delay

Control

Delay

Travel

Speed

Marking quality

degrades as

thickness

decreases.

18A Arc Current

Plasma (N₂)

Shield (N₂)

Burn-through may

happen for thicknesses

< 1/16” (0.063”) /

1.6 mm.

(psi) /

(Bar)

Ball (psi) /

(Bar) Ball

(psi) /

(Bar) (Volts)

(in) ±0.005 /

(mm) ±0.1

(in) ±0.005 / (mm) ±0.1

(sec)

(sec)

(ipm) /

(mm/ min)

20 / 1.4

40

40 /

2.8

75

80 /

5.5

143 0.120 / 3.0

0.120 / 3.0

0

0.4

300 /

7620

Electrode

Shield Cap

Tip

Shield Gas

Distributor

Plasma Gas

Distributor

Cartridge

Shield Cup

This Art Is For Reference ONLY

Art # A-07958_AB

Advertising