Stainless steel, 100a, N₂ plasma / h₂o shield – Tweco Ultra-Cut Torch Data User Manual

Page 24: This art is for reference only

Advertising
background image

TORCH DATA for Ultra-Cut

8-24

Manual 0-4828

Rev BA

Stainless Steel

Flow Rates

100A

N₂ (SLPM / SCFH)

H₂O (GPH / LPH)

Preflow

17 / 35

7 / 26

N₂ Plasma / H₂O Shield

Cutflow

14 / 29

7 / 26

Shield Cup

Shield Cap

Shield Gas

Distributor

Tip

Plasma Gas Distributor

Electrode

Cartridge

21-1016

21-1036

21-1274

21-1053

21-1041

21-1089

21-1020

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Material

Thickness

Pre Flow

Pressure

(N₂)

Cut Flow Rates / Pressures

Arc

Voltage Cut Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion

Delay

Max Kerf Width

@ Rec. Speed

Plasma (N₂) Shield (H₂O)

ga

(in)

inch

(psi)

Ball (psi) Ball (psi)* (Volts) (in) ±0.005 (sec)

(in)

(in)

(sec)

(in)

(ipm)

(sec)

(in)

-

3/16

0.188

45

60

90

7

55

148

0.100

0.1

0.200 0.150

0.2

0.300

140

0.1

0.091

-

1/4

0.250

45

60

90

7

55

158

0.100

0.1

0.200 0.150

0.2

0.300

95

0.1

0.091

-

3/8

0.375

45

60

90

7

55

168

0.150

0.2

0.250 0.200

0.2

0.350

65

0.2

0.100

-

1/2

0.500

45

60

90

7

55

168

0.150

0.4

0.250 0.200

0.2

0.350

50

0.4

0.102

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Material

Thickness

Pre Flow

Pressure

(N₂)

Cut Flow Rates / Pressures

Arc

Voltage Cut Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion

Delay

Max Kerf Width

@ Rec. Speed

Plasma (N₂) Shield (H₂O)

(mm)

(Bar)

Ball (Bar) Ball (Bar)* (Volts) (mm) ±0.1 (sec) (mm)

(mm)

(sec)

(mm)

(mm/

min)

(sec)

(mm)

5

3.1

60

6.2

7

3.8

149

2.5

0.1

5.1

3.8

0.2

7.6

3390

0.1

2.3

6

3.1

60

6.2

7

3.8

156

2.5

0.1

5.1

3.8

0.2

7.6

2670

0.1

2.3

8

3.1

60

6.2

7

3.8

163

3.2

0.2

5.7

4.5

0.2

8.3

2020

0.2

2.4

10

3.1

60

6.2

7

3.8

168

3.8

0.2

6.4

5.1

0.2

8.9

1590

0.2

2.5

12

3.1

60

6.2

7

3.8

168

3.8

0.4

6.4

5.1

0.2

8.9

1350

0.4

2.6

Marking

Pre Flow

Pressure

(N₂)

Marking Flow Rates /

Pressures

Arc

Voltage

Marking

Height

Pierce Ignition Height

THC and CNC

Delay

Control

Delay

Travel

Speed

Marking quality

degrades as

thickness

decreases.

18A Arc Current

Plasma (N₂)

Shield (N₂)

Burn-through may

happen for thicknesses

< 1/16” (0.063”) /

1.6 mm.

(psi) /

(Bar)

Ball (psi) /

(Bar) Ball

(psi) /

(Bar) (Volts)

(in) ±0.005 /

(mm) ±0.1

(in) ±0.005 / (mm) ±0.1

(sec)

(sec)

(ipm) /

(mm/ min)

20 / 1.4

50

40 /

2.8

75

80 /

5.5

150 0.120 / 3.0

0.120 / 3.0

0

0.4

300 /

7620

* Pressure of the water supply line should be regulated by customer pressure regulator.

Note 1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic sensing circuit.
Note 2: Water source used for shield must be demineralized.

Electrode

Shield Cap

Tip

Shield Gas

Distributor

Plasma Gas

Distributor

Cartridge

Shield Cup

This Art Is For Reference ONLY

Art # A-07958_AB