TORCH DATA for Ultra-Cut

Aluminum

400A

N₂ Plasma / H₂O Shield

Flow Rates

N₂ (SLPM / SCFH)

H₂O (GPH /

LPH)

Preflow

22 / 47

8 / 30

Cutflow

72 / 153

8 / 30

Shield Cup

Shield Cap

Shield Gas Distributor

Tip

Plasma Gas Distributor

Electrode

Cartridge

21-1305

21-1501

21-1500

21-1302

21-1043

21-1502

21-1300

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Material

Thickness

Pre Flow

Pressure

(N2)

Cut Flow Rates / Pressures

Arc Voltage Cut Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion Delay

Max Kerf

Width

@ Rec. Speed

Plasma (N₂) Shield (H₂O)

ga (in)

inch

(psi)

Ball

(psi) Ball (psi)*

(Volts) (in) ±0.005 (sec)

(in)

(in)

(sec)

(in)

(ipm)

(sec)

(in)

- 1/2 0.500

17

150 119

8

NA

168

0.250

0.3

0.350 0.450

0.2

Not R

ec

ommended without

Ele

va

tion Heigh

t

140

0.2

0.185

- 5/8 0.625

17

150 119

8

NA

177

0.300

0.7

0.450 0.550

0.2

110

0.5

0.195

- 3/4 0.750

17

150 119

8

NA

180

0.350

0.8

0.450 0.550

0.2

90

0.6

0.195

- 7/8 0.875

17

150 119

8

NA

180

0.350

0.9

0.450 0.550

0.2

75

0.7

0.215

-

1

1.000

17

150 119

8

NA

182

0.350

1.2

0.450 0.550

0.2

70

0.9

0.215

- 1 1/4 1.250

17

150 119

8

NA

190

0.350

1.4

0.450 0.550

0.2

65

1.0

0.215

- 1 1/2 1.500

17

150 119

8

NA

191

0.350

1.6

0.450 0.550

0.2

55

1.2

0.215

- 1 3/4 1.750

17

150 119

8

NA

200

0.420

1.8

0.500 0.600

0.2

40

1.4

0.240

-

2

2.000

17

150 119

8

NA

211

0.420

2.5

0.500 0.600

0.2

30

1.9

0.295

- 2 1/4 2.250

17

150 119

8

NA

215

0.420

4.8

0.500 0.600

0.2

20

2.2

0.320

- 2 1/2 2.500

17

150 119

8

NA

222

0.420

3.0

Edge Start

0.2

12

3.0

0.335

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Material

Thickness

Pre Flow

Pressure

(N2)

Cut Flow Rates / Pressures

Arc Voltage Cut Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC Motion

Delay

Max Kerf

Width

@ Rec. Speed

Plasma (N₂) Shield (H₂O)

(mm)

(Bar)

Ball (Bar) Ball (Bar)*

(Volts)

(mm) ±0.1 (sec)

(mm)

(mm)

(sec)

(mm)

(mm/

min)

(sec)

(mm)

12

1.2

150

8.2

8

NA

166

6.1

0.2

8.3

10.9

0.2

Not R

ec

ommended without

Ele

va

tion Heigh

t

3720

0.1

4.6

15

1.2

150

8.2

8

NA

175

7.3

0.6

10.7

13.3

0.2

3000

0.4

4.9

20

1.2

150

8.2

8

NA

180

8.9

0.8

11.4

14.0

0.2

2170

0.6

5.1

25

1.2

150

8.2

8

NA

182

8.9

1.2

11.4

14.0

0.2

1790

0.9

5.5

30

1.2

150

8.2

8

NA

188

8.9

1.3

11.4

14.0

0.2

1690

1.0

5.5

35

1.2

150

8.2

8

NA

191

8.9

1.5

11.4

14.0

0.2

1520

1.1

5.5

40

1.2

150

8.2

8

NA

194

9.4

1.7

11.8

14.4

0.2

1280

1.3

5.7

50

1.2

150

8.2

8

NA

210

10.7

2.4

12.7

15.2

0.2

790

1.8

7.3

60

1.2

150

8.2

8

NA

218

10.7

4.0

Edge Start

0.2

420

2.6

8.3

Marking

45A Arc Current

Burn-through

may happen for

thicknesses <

1/16” (0.063”) /

1.6mm.

Pre Flow

Pressure

(N₂)

Marking Flow Rates /

Pressures

Arc

Voltage

Marking

Height

Pierce Ignition Height THC and CNC Delay Control

Delay

Travel

Speed

Marking

quality

degrades as

thickness

decreases.

Plasma (N₂) Shield (N₂)

(psi) /

(Bar)

Ball (psi) /

(Bar) Ball

(psi) /

(Bar)

(Volts)

(in) ±0.005 /

(mm) ±0.1

(in) ±0.005 / (mm) ±0.1

(sec)

(sec) (ipm) / (mm/

min)

15 / 1.0 80

60 /

4.1

NA 90 /

6.2

105

0.180 / 4.6

0.180 / 4.6

0

0

200 / 5080

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.

BOLD TYPE indicates maximum piercing parameters.

* Pressure of the water supply line should be regulated by customer pressure regulator.

Note 1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic sensing circuit.

Note 2: Water source used for shield must be demineralized.

This Art Is For Reference Only

Shield Cup

Shield Cap

Shield Gas

Distributor

Tip

Gas

Distributor

Electrode

Cartridge Assembly

Art# A-10445

Advertising