Mild steel 400a bevel cut o₂ plasma / air shield, This art is for reference only – Tweco Ultra-Cut Torch Data User Manual

Page 73

Advertising
background image

Manual 0-4828

Rev BA

8-73

TORCH DATA for Ultra-Cut

8.08 Robotic and Bevel Cutting 400 Amp

Mild Steel

400A Bevel Cut

O₂ Plasma / Air Shield

Flow Rates (SLPM / SCFH)

O₂

Air

Preflow

- / -

232 / 491

Cutflow

33 / 70

203 / 430

Shield Cup

Shield Cap

Shield Gas Distributor

Tip

Plasma Gas Distributor

Electrode

Cartridge

21-1305

21-1304

21-1310

21-1309

21-1042

21-1308

9-7921

21-1300

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Effective

Material

Thickness

Min.

Clearance

Pre Flow

Pressure

(Air)

Cut Flow Rates / Pressures

Effective Cut

Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion

Delay

Max Kerf

Width

@ Rec. Speed

Plasma (O₂) Shield (Air)

inch

(in)

(psi)

Ball (psi) Ball

(psi)

(in)

(sec)

(in)

(in)

(sec)

(in)

(ipm)

(sec)

(in)

0.500

0.080

15

80

90

-

80

0.200 - 0.600

0.3

0.400

0.200

0.2

Not R

ec

ommended without

Ele

va

tion Heigh

t

150

0.2

0.195

0.625

0.080

15

80

90

-

80

0.200 - 0.600

0.4

0.400

0.300

0.2

130

0.3

0.200

0.750

0.080

15

80

90

-

80

0.200 - 0.600

0.6

0.400

0.300

0.2

115

0.8

0.215

0.875

0.080

15

80

90

-

80

0.200 - 0.600

0.9

0.400

0.500

0.2

100

0.9

0.200

1.000

0.080

15

80

90

-

80

0.200 - 0.600

1.1

0.400

0.550

0.2

80

0.9

0.200

1.250

0.080

15

80

90

-

80

0.200 - 0.600

1.5

0.400

0.650

0.2

60

1.3

0.220

1.500

0.080

15

80

90

-

80

0.200 - 0.600

4.0

0.450

0.600

0.2

45

2.5

0.230

1.750

0.080

15

80

90

-

80

0.200 - 0.600

4.5

0.450

0.650

0.2

40

4.0

0.225

2.000

0.080

15

80

90

-

80

0.200 - 0.600

7.0

0.450

0.750

0.2

30

6.0

0.225

2.250

0.080

15

80

90

-

80

0.200 - 0.600

3.5

Edge Start

0.2

25

3.5

0.235

2.500

0.080

15

80

90

-

80

0.200 - 0.600

3.0

Edge Start

0.2

15

3.0

0.235

3.000

0.080

15

80

90

-

80

0.200 - 0.600

3.0

Edge Start

0.2

10

3.0

0.300

3.500

0.080

15

80

90

-

80

0.200 - 0.600

3.0

Edge Start

0.2

4

3.0

0.360

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Effective

Material

Thickness

Min.

Clearance

Pre Flow

Pressure

(Air)

Cut Flow Rates / Pressures

Effective Cut

Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion

Delay

Max Kerf

Width

@ Rec. Speed

Plasma (O₂) Shield (Air)

(mm)

(mm)

(Bar)

Ball (Bar) Ball (Bar)

(mm)

(sec)

(mm)

(mm)

(sec)

(mm)

(mm/

min)

(sec)

(mm)

12

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

0.3

10.2

4.5

0.2

Not R

ec

ommended without

Ele

va

tion Heigh

t

3920

0.2

4.9

15

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

0.4

10.2

6.9

0.2

3440

0.3

5.0

20

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

0.7

10.2

9.1

0.2

2810

0.8

5.3

25

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

1.1

10.2

13.8

0.2

2100

0.9

5.1

30

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

1.4

10.2

15.8

0.2

1660

1.2

5.4

35

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

2.8

10.8

15.9

0.2

1330

1.9

5.7

40

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

4.1

11.4

15.6

0.2

1110

2.9

5.8

50

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

6.7

11.4

18.7

0.2

790

5.7

5.7

60

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

3.3

Edge Start

0.2

520

3.3

6.0

70

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

3.0

Edge Start

0.2

320

3.0

6.8

80

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

3.0

Edge Start

0.2

210

3.0

8.1

90

2.0

1.0

80

6.2

-

5.5

5.1 - 15.2

3.0

Edge Start

0.2

90

3.0

9.3

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.

BOLD TYPE indicates maximum piercing parameters.

* Pressure of the water supply line should be regulated by customer pressure regulator.

Note 1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic sensing circuit.

Note 2: Water source used for shield must be demineralized.

THC Pierce Delay values shown are the minimum values. It is recommended that this value should be increased depending on the application.

This Art Is For Reference Only

Art# A-10270_AB

Shield Cup

Shield Cap

Shield Gas

Distributor

Tip

Gas

Distributor Electrode

Tube

Cartridge Assembly

Advertising