Stainless steel, N₂ plasma / h₂o shield, This art is for reference only – Tweco Ultra-Cut Torch Data User Manual

Page 14

Advertising
background image

TORCH DATA for Ultra-Cut

8-14

Manual 0-4828

Rev BA

Stainless Steel

Flow Rates

50A

N₂ (SLPM / SCFH)

H₂O (GPH / LPH)

Preflow

17 / 37

4 / 15

N₂ Plasma / H₂O Shield

Cutflow

18 / 38

4 / 15

Shield Cup

Shield Cap

Shield Gas Distributor

Tip

Plasma Gas Distributor

Electrode

Cartridge

21-1016

21-1034

21-1274

21-1180

21-1041

21-1181

21-1020

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Material

Thickness

Pre Flow

Pressure

(N2)

Cut Flow Rates / Pressures

Arc

Voltage Cut Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion

Delay

Max Kerf Width

@ Rec. Speed

Plasma (N₂)

Shield (H₂O)

ga

(in)

inch

(psi)

Ball

(psi)

Ball (psi)* (Volts) (in) ±0.005 (sec)

(in)

(in)

(sec)

(in)

(ipm)

(sec)

(in)

16

-

0.063

60

62

120

4

55

133

0.110

0.0 0.125 0.120

0.5

0.200

210

0.0

0.043

14

-

0.078

60

62

120

4

55

132

0.110

0.1 0.125 0.120

0.5

0.200

170

0.1

0.043

12

-

0.109

60

62

120

4

55

126

0.110

0.2 0.125 0.120

0.5

0.200

150

0.2

0.047

10

-

0.141

60

62

120

4

55

139

0.110

0.3 0.125 0.120

0.5

0.200

120

0.3

0.050

-

3/16 0.188

60

62

120

4

55

157

0.110

0.5 0.125 0.120

0.5

0.200

50

0.5

0.050

GCM-2010

SC-3000 Torch Height Control (THC)

Basic THC

CNC Control

Material

Thickness

Pre Flow

Pressure

(N2)

Cut Flow Rates / Pressures

Arc

Voltage Cut Height

THC

Pierce

Delay

Pierce

Ignition

Height

Elevation

Height

Control

Delay

Pierce

Height

without

Elevation

Travel

Speed

CNC

Motion

Delay

Max Kerf Width

@ Rec. Speed

Plasma (N₂)

Shield (H₂O)

(mm)

(Bar)

Ball

(Bar)

Ball (Bar)* (Volts) (mm) ±0.1 (sec) (mm)

(mm)

(sec)

(mm)

(mm/

min)

(sec)

(mm)

2

4.1

62

8.3

4

3.8

123

2.8

0.1

3.2

3.0

0.5

5.1

4310

0.1

1.1

2.5

4.1

62

8.3

4

3.8

128

2.8

0.1

3.2

3.0

0.5

5.1

3980

0.1

1.2

3

4.1

62

8.3

4

3.8

130

2.8

0.2

3.2

3.0

0.5

5.1

3660

0.2

1.2

4

4.1

62

8.3

4

3.8

145

2.8

0.4

3.2

3.0

0.5

5.1

2410

0.4

1.3

Marking

Pre Flow

Pressure

(N₂)

Marking Flow Rates / Pressures

Arc

Voltage

Marking

Height

Pierce Ignition Height

THC and CNC

Delay

Control

Delay

Travel

Speed

Marking quality

degrades as

thickness

decreases.

16A Arc Current

Plasma (N₂)

Shield (N₂)

Burn-through may

happen for thicknesses

< 1/16” (0.063”) /

1.6mm.

(psi) / (Bar) Ball

(psi) /

(Bar)

Ball

(psi) /

(Bar)

(Volts) (in) ±0.005 /

(mm) ±0.1

(in) ±0.005 / (mm) ±0.1

(sec)

(sec)

(ipm) /

(mm/ min)

20 / 1.4

40

40 / 2.8 75 80 / 5.5 120

0.120 / 3.0

0.120 / 3.0

0

0.4 300 / 7620

BOLD TYPE indicates maximum piercing parameters.
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic sensing circuit.
Note2: Water source used for shield must be demineralized.

Electrode

Shield Cap

Tip

Shield Gas

Distributor

Plasma Gas

Distributor

Cartridge

Shield Cup

This Art Is For Reference ONLY

Art # A-07958_AB