Tweco Ultra-Cut Torch Data User Manual

Page 4

Advertising
background image

TORCH DATA for Ultra-Cut

8-4

Manual 0-4828

Rev BA

General Definitions:

THC

Torch Height Control

Arc Voltage

Voltage measurement between the electrode and the work piece which is used to control
the torch to work distance during cutting.

Cut Height

Distance between the plasma torch and the work piece during cutting.

Pierce Ignition Height Torch to work distance during arc transfer. This setting is typically lower when using a THC

with elevation height in order to increase transfer reliability.

Elevation Height

Distance from Pierce Ignition Height that the torch raises to in order to prevent torch damage
during plate piercing.

THC Pierce Delay

Time following arc transfer that the torch remains at Pierce or Elevation Height. This is often
longer than the CNC Motion Delay in order to allow the torch to clear the pierce puddle.

CNC Motion Delay

Time following arc transfer to allow the arc to piece through the plate before the table XY
motion starts.

Control delay

Often called AVC delay, this is time starting when torch is moved to Cut Height until THC
starts controlling height to the sampled arc voltage.

Cut Speed

Recommended cut speed based on the material thickness, torch parts and gas combination
used.

Kerf Width

The width of material removed during the cut.