Shield – Tweco XT-300 Torch for OEM UC-300 User Manual

Page 47

Advertising
background image

Manual 0-4829 Rev AN

8-49

TORCH DATA for Ultra-Cut

(ga)

(in)

inch

(PSI)

(Ball) (PSI)

(Ball)

(PSI)

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

3/8

0.375

20

100

100

NA

110

165

0.300

180

0.400

0.4

0.113

1/2

0.500

20

100

100

NA

110

168

0.300

150

0.350

0.2

0.119

5/8

0.625

20

100

100

NA

110

170

0.300

110

0.350

0.3

0.120

3/4

0.750

20

100

100

NA

110

172

0.300

70

0.400

0.4

0.130

7/8

0.875

20

100

100

NA

110

178

0.350

55

0.450

0.5

0.139

1

1.000

20

100

100

NA

110

180

0.350

40

0.500

0.7

0.150

1 1/4

1.250

20

100

100

NA

110

185

0.400

32

0.161

1 1/2

1.500

20

100

100

NA

110

195

0.400

25

0.170

2

2.000

20

100

100

NA

110

201

0.400

15

0.205

(Bar)

(Ball) (Bar)

(Ball)

(Bar)

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

1.4

100

6.9

NA

7.6

166

7.6

4500

10.2

0.4

2.9

1.4

100

6.9

NA

7.6

168

7.6

3850

8.9

0.2

3.0

1.4

100

6.9

NA

7.6

170

7.6

2800

8.9

0.3

3.0

1.4

100

6.9

NA

7.6

174

7.6

1600

10.2

0.5

3.3

1.4

100

6.9

NA

7.6

180

8.9

1050

12.7

0.7

3.8

1.4

100

6.9

NA

7.6

185

10.2

800

Edge
Start

0.0

4.1

1.4

100

6.9

NA

7.6

195

10.2

640

Edge
Start

0.0

4.3

1.4

100

6.9

NA

7.6

198

10.2

450

4.8

1.4

100

6.9

NA

7.6

200

10.2

380

5.2

(PSI) /

(Bar)

(Ball)

(PSI) /

(Bar)

(Ball)

(PSI) /

(Bar)

Volts

in ±0.005 /

mm ±0.1

ipm /

mm/min

in ±0.005 /

mm ±0.1

(sec)

15

60

80

0.120

300

0.120

1.0

4.1

5.5

3.0

7600

3.0

140

0

Plasma (N

2

) Shield

(N

2

)

80

NA

Marking

20A Arc Current

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Transfer

Height

Pierce

Delay

Marking

quality

degrades

as

thickness

decreases

Aluminum
200A
H35 Plasma / N

2

Shield

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later

22-1022

22-1015

< 1" / 25mm 22-1073
1" / 25mm + 22-1094

22-1284

22-1095

Material

Thickness

Pre Flow

Pressure

(N

2

)

NOTE: Lock pierce height between 0.5" to 1" to avoid torch hitting the pierce metal puddle.

Shield

Retainer

Shield Cap

Shield Gas

Distributor

Tip

Plasma Gas

Distributor

Electrode

Cartridge

22-1043

22-1096

Initial

Piercing

Height

Pierce

Delay

Edge Start
Edge Start
Edge Start

Kerf Width

@ Rec.

Speed

Plasma (H35)

Shield (N

2

)

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Cut Flow Rates /

Pressures

Arc

Voltage

Kerf Width

@ Rec.

Speed

Plasma (O

2

) Shield

(Air)

(mm)

Material

Thickness

Pre Flow

Pressure

(Air)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

50

Edge Start

25
32

38

44

Edge Start

12
15
20

10

Electrode

Shield Retainer

Tip

Art # A-08567

Plasma Gas

Distributor

Cartridge Assembly

This Art Is For Reference ONLY

Shield Cap

Shield Gas
Distributor

Advertising