Stainless steel 300a bevel cut n, Plasma / h, O shield – Tweco XT-300 Torch for OEM UC-300 User Manual

Page 73

Advertising
background image

Manual 0-4829 Rev AN

8-75

TORCH DATA for Ultra-Cut

Shield

22-1046

in

in

psi

Ball

psi

Ball

psi

(ipm)

(in)

(sec)

(in)

3/8

0.08

20

120

100

8

55

140

0.350

0.3

0.144

1/2

0.08

20

120

100

8

55

100

0.350

0.5

0.154

5/8

0.08

20

120

100

8

55

75

0.350

0.1

0.153

3/4

0.08

20

120

100

8

55

55

0.500

0.7

0.173

7/8

0.08

20

120

100

8

55

45

0.500

1.1

0.210

1

0.08

20

120

100

8

55

40

0.500

1.3

0.210

1 1/4

0.08

20

120

100

8

55

30

0.500

2.0

0.230

1 1/2

0.08

20

120

100

8

55

25

0.232

1 3/4

0.08

20

120

100

8

55

18

0.237

2

0.08

20

120

100

8

55

12

0.253

mm

mm

bar

Ball

bar

Ball bar

(mm/min)

(mm)

(sec)

(mm)

10

2.00

1.4

120

6.9

8

3.8

3400

8.9

0.3

3.7

12

2.00

1.4

120

6.9

8

3.8

2760

8.9

0.5

3.9

15

2.00

1.4

120

6.9

8

3.8

2080

9.4

0.6

3.9

20

2.00

1.4

120

6.9

8

3.8

1320

12.7

0.8

4.7

25

2.00

1.4

120

6.9

8

3.8

1030

12.7

1.3

5.3

32

2.00

1.4

120

6.9

8

3.8

760

12.7

2.0

5.8

38

2.00

1.4

120

6.9

8

3.8

640

5.9

44

2.00

1.4

120

6.9

8

3.8

470

6.0

50

2.00

1.4

120

6.9

8

3.8

320

6.4

M

in

imu

m

C

lear

a

n

ce

Ef

fec

tive

Ma

te

ri

a

l

T

h

ic

knes

s

Pierce

Delay

.350-.550

Travel

Speed

Initial

Piercing

Height

Edge Start

Efeective Cut Height

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield
(H

2

O)*

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.

Edge Start
Edge Start

Edge Start

.200-.550
.300-.550
.300-.550

Stainless Steel
300A Bevel Cut
N

2

Plasma / H

2

O Shield

Mi

n

im

u

m

C

lear

a

n

ce

(in)

.150-.550

Edge Start

.350-.550

.350-.550
.350-.550

Edge Start

.150-.550
.150-.550

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield
(H

2

O)*

Ef

fec

tive

Ma

te

ri

a

l

Th

ic

kn

e

ss

Effective Cut Height

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

22-1089

22-1022

22-1015

22-1284

22-1066

* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically
with the ohmic sensing circuit.
Note2: Water source used for shield must be demineralized.

Plasma Gas

Distributor

Electrode

Cartridge

Shield

Retainer

Shield Gas

Distributor

Tip

22-1043

(mm)

3.8-13.97
3.8-13.97

8.9-13.97
8.9-13.97
8.9-13.97

3.8-13.97
5.8-13.97
7.6-13.97
8.9-13.97

Cartridge

Electrode

Shield

Shield Gas
Distributor

Tip

Plasma Gas

Distributor

Shield Retainer

Art # A-08552

This Art Is For Reference ONLY

Advertising