TORCH DATA for Ultra-Cut

8-50

Manual 0-4829 Rev AN

(ga)

(in)

inch

(PSI)

(Ball) (PSI) (Ball) (PSI)

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

1/2

0.500

20

100

90

5

55

168

0.250

110

0.300

0.3

0.120

5/8

0.625

20

80

100

5

55

170

0.300

105

0.350

0.5

0.126

3/4

0.750

20

80

100

5

55

175

0.300

90

0.350

0.6

0.127

7/8

0.875

20

80

100

5

55

180

0.300

75

0.350

0.8

0.133

1

1.000

20

80

100

5

55

194

0.350

50

0.400

1.0

0.144

1 1/4

1.250

20

80

100

5

55

208

0.400

25

0.450

2.0

0.180

1 1/2

1.500

20

80

100

5

55

210

0.400

20

0.500

3.000

0.197

1 3/4

1.750

20

80

100

5

55

212

0.400

18

0.201

2

2.000

20

80

100

5

55

215

0.400

12

0.204

(Bar)

(Ball) (Bar) (Ball) (Bar)

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

1.4

100

6.3

5

3.8

167

6.3

2900

7.6

0.3

3.0

1.4

80

6.9

5

3.8

170

7.5

2700

8.9

0.5

3.2

1.4

80

6.9

5

3.8

176

7.5

2200

8.9

0.6

3.3

1.4

80

6.9

5

3.8

194

8.9

1300

10.2

1.0

3.6

1.4

80

6.9

5

3.8

208

10.2

630

11.4

2.0

4.6

1.4

80

6.9

5

3.8

210

10.2

500

12.7

3.0

5.0

1.4

80

6.9

5

3.8

212

10.2

460

5.1

1.4

80

6.9

5

3.8

215

10.2

300

5.2

(PSI) /

(Bar)

(Ball)

(PSI) /

(Bar)

(Ball)

(PSI) /

(Bar)

Volts

in ±0.005 /

mm ±0.1

ipm /

mm/min

in ±0.005 /

mm ±0.1

(sec)

15

60

80

0.120

300

0.120

1.0

4.1

5.5

3.0

7600

3.0

140

0

Plasma (N

2

) Shield

(N

2

)

80

NA

Marking

20A Arc Current

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Transfer

Height

Pierce

Delay

Marking

quality

degrades

as

thickness

decreases

Plasma Gas

Distributor

Electrode

Cartridge

Shield

Retainer

Shield Cap

Shield Gas

Distributor

Tip

22-1043

22-1089

22-1022

22-1015

22-1049

22-1284

22-1067

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield
(H

2

O)*

Edge Start

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Edge Start

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

Plasma (N

2

)

Shield
(H

2

O)*

(mm)

Edge Start

12
15
20
25

* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Note2: Water source used for shield must be demineralized.

Aluminum
200A
N

2

Plasma / H

2

O Shield

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.

50

Edge Start

32
38

44

Cartridge

Electrode

Shield

Shield Gas
Distributor

Tip

Plasma Gas

Distributor

Shield Retainer

Art # A-07917_AC

This Art Is For Reference ONLY

Advertising