TORCH DATA for Ultra-Cut

(ga)

(in)

inch

psi

Ball

psi

Ball

psi

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

1/4

0.250

20

120

100

NA

120

163

0.400

300

0.400

0.1

0.182

3/8

0.375

20

120

100

NA

120

163

0.400

275

0.400

0.2

0.186

1/2

0.500

20

120

100

NA

120

153

0.300

210

0.400

0.3

0.174

5/8

0.625

20

120

100

NA

90

160

0.300

140

0.350

0.4

0.169

3/4

0.750

20

120

100

NA

90

159

0.300

110

0.350

0.5

0.172

7/8

0.875

20

120

100

NA

90

162

0.300

95

0.400

0.6

0.183

1 1.000

20

120

100

NA

120

165

0.350

85

0.450

0.7

0.190

1 1/4

1.250

20

120

100

NA

120

168

0.400

60

0.205

1 1/2

1.500

20

120

100

NA

120

177

0.400

45

0.215

1 3/4

1.750

20

120

100

NA

120

182

0.400

35

0.226

2

2.000

20

120

100

NA

120

188

0.400

25

0.215

bar

Ball

bar

Ball

bar

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

1.4

120

6.9

NA

8.3

163

10.2

7620

10.2

0.1

4.7

1.4

120

6.9

NA

8.3

163

10.2

7290

10.2

0.2

4.7

1.4

120

6.9

NA

8.3

162

9.8

6740

10.2

0.2

4.7

1.4

120

6.9

NA

8.3

155

8.2

5700

10.2

0.3

4.5

1.4

120

6.9

NA

6.2

158

7.6

4050

9.2

0.4

4.3

1.4

120

6.9

NA

6.2

160

7.6

2680

9.3

0.5

4.5

1.4

120

6.9

NA

8.3

165

8.7

2190

11.3

0.7

4.8

1.4

120

6.9

NA

8.3

168

10.2

1510

5.2

1.4

120

6.9

NA

8.3

177

10.2

1150

5.5

1.4

120

6.9

NA

8.3

182

10.2

910

5.7

1.4

120

6.9

NA

8.3

185

10.2

670

5.8

(PSI) /

(Bar)

(Ball)

(PSI) /

(Bar)

(Ball)

(PSI) /

(Bar)

Volts

in ±0.005 /

mm ±0.1

ipm /

mm/min

in ±0.005 /

mm ±0.1

(sec)

15

60

90

0.120

300

0.120

1.0

4.1

6.2

3.0

7600

3.0

Initial

Transfer

Height

Pierce

Delay

Marking

quality

degrades

as

thickness

decreases

Burn-through

may occur

for thicknesses

< 1/16" (0.063") / 1.6

mm.

Plasma (N

2

) Shield (N

2

)

80

NA

135

0

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Plasma Gas

Distributor

Electrode

Cartridge

Shield

Retainer

Shield Cap

Shield Gas

Distributor

Tip

22-1041

22-1091

22-1022

22-1015

< 1" / 25mm 22-1038,

1" / 25mm + 22-1039

22-1284

22-1065

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Edge Start
Edge Start

Kerf Width

@ Rec.

Speed

Plasma

(H35)

Shield (N

2

)

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Aluminium
300A
H35 Plasma / N

2

Shield

15

10
12

(mm)

6

8

Kerf Width

@ Rec.

Speed

Plasma

(H35)

Shield (N

2

)

Edge Start
Edge Start

Material

Thickness

Pre Flow

Pressure

(N

2

)

Cut Flow Rates /

Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

20
25
32

Edge Start

50

Edge Start

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.